![Hydac FCC-CM 5/15 Скачать руководство пользователя страница 33](http://html.mh-extra.com/html/hydac/fcc-cm-5-15/fcc-cm-5-15_operating-and-maintenance-instructions-manual_2191270033.webp)
Operating the volume meter (optional accessories)
FCC-CM
en(us)
Page 33 / 60
BEWA FCC-CM 3648206 en-us 2016-07-08.docx
2016-07-08
Calibrating the totals counter
Pressing the TOTAL button will cause the accumulator memory value to be
displayed for as long as the button is being pressed, but only as long as no
volume pulses are coming in (see also calibration or correction factor).
The correction factor programmed at the factory shows during the basic me-
ter precision test with an electronic display attached.
Example:
Quantity dispensed:
4.2 liters
Quantity displayed:
4.0 liters
Correction factor k:
4.2 / 4.0 = 1.05
Pressing the TOTAL and the RESET button simultaneously in this sequence
will cause the programmed correction factor to be displayed, as long as both
buttons are depressed.
The keyboard commands are ignored as soon as volume signals arrive.