5.3.1 Contact assignment at POWER connection
The POWER connection plug has the following contact assign-
ment.
PIN
Signal
Description
1
DC IN
+12 … 24 V DC supply voltage
2
n.c.
Not connected
3
GND
Supply voltage GND
4
n.c.
Not connected
5
n.c.
Not connected
S
Shield
Shield
Tab. 7: POWER contact assignment
5.3.2 Contact assignment at CAN connection
The CAN connection socket has the following assignment.
PIN
Signal
Description
1
SH
Shield
2
VIN
+12 … 24 V DC voltage output
3
GND
GND voltage output
4
CANH
CAN high, differential data pair
5
CANL
CAN low, differential data pair
S
Shield
Shield
Tab. 8: CAN contact assignment