8 Troubleshooting
The following errors may arise when commissioning or operat-
ing the unit.
Error
Cause
Remedy
The DATA+ BOX
does not start.
The POWER LED
does not light up.
Supply voltage in-
correct or not
present.
Check the supply
voltage.
No supply voltage
at the sensors/mod-
ules for the RS 485
and/or CAN
Supply voltage in-
correct or not
present.
Contact HYDAC
Service.
Setting up not pos-
sible.
The DATA+ BOX is
not reachable via
LAN.
Connectivity prob-
lem through other
DHCP servers in
the network.
Connect the
DATA+ BOX di-
rectly to the end de-
vice via ETH 0.
Disconnect the
DHCP sever from
the network.
Tab. 15: Troubleshooting