4 Commissioning
Prior to commissioning, check to see that the filter elements have been installed in the
housing. For more information, see the section on
Changing the Filter Elements
.
Checking the filter elements:
1. Carefully undo the safety screws (1) (with chain) on the cover plate.
2. Open the quick-action fasteners and lift up the cover plates.
3. Make sure that the filter elements have been correctly inserted.
4. Lightly oil or grease the flanges.
5. Place the housing cover on the flanges of the tank.
6. Apply the quick-action fasteners (6), align them and close them. (tightening torque =
27 Nm)
7. Screw the safety screws (1) back in.
Filling and air-bleeding:
1. The "dirt side" oil drain plug (2) and the "clean side" oil drain screw plug (3) have to be
closed tight.
2. Open the air-bleed valve (4) on the cover plate.
3. Fill the filter slowly via the system.
4. After the air in the filter has escaped completely, close the air-bleed valve (4) on the
cover plate.
5. Check the filter unit for leakage.