ALPC 9000 series
Performing Maintenance
HYDAC FILTER SYSTEMS GMBH
en
Page 46 / 68
BEWA ALPC9000 3601005 en 2011-04-07.doc
2011-04-06
Performing Maintenance
The maintenance and servicing to be performed periodically is described here. The
ALPC's serviceability, operational reliability and life substantially depend on
performing maintenance and servicing work regularly and carefully.
Maintenance intervals / plan
Details on page
8 hours or daily
300 hours or every
six months
Every
6000
hours
of operation or
yearly
Perform a lamp test on the mains box
X
Test / fill the flushing fluid tank
X
Test / empty the flushing fluid return tank
X
Check / clean the sealing disk on the vacuum hand
X
Check the sealing ring on the pressure dome
X
Clean the oil collecting pan
X
Check all warning guidelines / safety stickers for
legibility
X
Check all compressed air hoses for:
- Damage due to kinks
- Flexibility
- Tightness / leakages
- Tight fit of the screw-in and plug-in connections
X
Check all the electrical connections.
Look for any damage to wires, connectors, sensors,
cabling and electrical equipment in the control cabinet.
X =
other
volta
ge
Check all compressed air hoses for:
- Damage due to kinks
- Flexibility
- Tightness / leakages
- Tight fit of the screw-in and plug-in connections
X =
other
volta
ge
Check that all of the shut-off valves are working
properly
X
Check the maintenance unit for:
- Adjusted air pressure
- Condensate / water
X
Check all flushing and return hoses for:
- Damage due to kinks
X