Monitoring the unit's sensors/displays
OXiStop OXS
en
Page 41 / 108
MoWa OXS 3992763e en-us 2018-08-10.docx
2018-08-10
Connecting electronic fluid level/temperature sensor HNS
The unit is equipped with a float-based sensor with an integrated fluid
level/temperature sensor.
The surface of the fluid in the fluid level suction tube corresponds to the
current position of the underside of the diaphragm.
The sensor is located in the valve block and it is used to monitor the
diaphragm stroke and thus the differential operating volume available in the
tank.
If the oil level is too high or too low, the sensor issues an alarm signal to
switch off the unit.
The temperature of the oil is monitored via the integrated electric temperature
sensor.
Details on connection and the terminal allocations can be found in the
instructions for the HNS.
Check the settings in accordance with the specifications given in chapter
"Check / adjust electronic level / temperature sensor HNS" on page 77.