HDA 4000W intrinsically safe, non-sparking, dustproof enclosure: ATEX and IECEx
12
Status: 2021-11-22
HYDAC ELECTRONIC GMBH
Part
no.: 670063
9
Model code to identify the delivered part
Accuracy
Mechanical connection
HDA 4 7 X 0 - W11 - XXXXX - E N E - XXX (psi)
Measuring
Ranges
Approval
E = ATEX, IECEx (further details, see certificates)
Modification number
(
psi
)
7 = 0.5 % FS max.
Mechanical connection
4 = G 1/4 A ISO 1179-2, external thread
7 = 9/16-18 UNF 2A (SAE 6), external thread
8 = 1/4-18 NPT, external thread
B = F250C Autoclave (9/16-18 UNF 2B), internal thread
C = SF250CX20, Autoclave (7/16-20 UNF 2B), internal thread
F = 1/4-18 NPT, internal thread
Output signal
Measuring ranges are shown in bar or psi (in case of psi see additional psi declaration in
model code)
000 = Standard
(other numbers are used for e.g.: Version, orifice, pin connection,plug at the jacketed cable)
W11 = Bluetooth 4.0
Low Energy
Protection types and application fields
ATEX
IECEx
E =
Ex I M1 Ex ia I Ma
Ex Il 2G Ex ia IIB T4 Gb -30°C<Ta<60°C
Ex ia I Ma
Ex ia IIB T4 Gb -30°C<Ta<60°C
Additional declaration for psi measurement ranges (not applicable for bar version)