14
EDS 820 IO-Link
Edition: 2020-04-21
HYDAC ELECTRONIC GMBH
Part No.: 669916 E
11.2 Setting ranges for the switching outputs
Measurement
range
Lower limit of
RP / FL
Upper limit
of SP / FH
Minimum
difference betw.
RP and SP
or FL and FH
Increment*
in bar
in bar
in bar
in bar
0 .. 16
0.15
16.00 0.15
0.05
0 .. 25
0.25
25.00 0.25
0.05
0 .. 40
0.4
40.0 0.4
0.1
0 .. 100
1.0
100.0 1.0
0.2
0 .. 250
2.5
250.0 2.5
0.5
0 .. 400
4
400 4
1
0 .. 600
6
600 6
1
* All ranges shown in the table can be adjusted by the increments shown.
SP = switch point
RP = switch-back point
FL = pressure window lower value
FH = pressure window upper value
Measurement
range
Lower limit of
RP / FL
Upper limit
of SP / FH
Minimum
difference betw.
RP and SP
or FL and FH
Increment*
in psi
in psi
in psi
in psi
0 .. 500
5
500 5
1
0 .. 1000
10
1000 10
2
0 .. 3000
30
3000 30
5
0 .. 6000
60
6000 60
10
0 .. 9000
90
9000 90
20
* All ranges shown in the table can be adjusted by the increments shown.