Standard Variable "Standard Command" index=2 id=V_SystemCommand
data type: 8-bit UInteger
allowed values: 128 = Device Reset, 129 = Application Reset, 130 = Restore Factory Settings, 160 = Reset Primary
Min/Max, 164 = Reset All Min/Max, 165 = Auto-Zero Primary Input, 169 = Store All Input Offsets
access rights: wo
modifies other variables
octet
0
bit offset
7 - 0
element bit
7 - 0
Variable "BDC1 Thresholds" index=60 id=V_Bdc1Thresholds
data type: 32-bit Record (subindex access not supported)
access rights: rw
modifies other variables
excluded from data storage
subindex
bit
offset
data type
allowed
values
default
value
mod. other var.
name
description
1
16
16-bit Integer
See
10.2
1250 V_PrimaryValueSp1 Setpoint SP1
Lower limit of RP /
FL in bar
2
0
16-bit Integer
See
10.2
1750 V_PrimaryValueSp1 Setpoint SP2
Upper limit of SP /
FH in bar
SP = switch point RP = switch-back point FL = pressure window lower value FH = pressure window upper value
octet
0
1
2
3
bit offset
31 - 24
23 - 16
15 - 8
7 - 0
subindex
1
1
2
2
element bit
15 - 8
7 - 0
15 - 8
7 - 0
Standard Variable "Device Access Locks" index=12 id=V_DeviceAccessLocks
data type: 16-bit Record (subindex access not
supported)
access rights: rw
subindex bit offset
data type
name
description
1
0
Boolean
Parameter (write)
Access Lock
2
1
Boolean
Data Storage Lock
For compatibility reasons only – it is recommended to to
keep subindex 2 „false“ in order to avoid any unwanted
system behavior if data storage is set via IO-Link master
Datenhaltung (Subindex 2) ist aus Kompatibilitätsgründen
vorhanden und sollte immer auf „False“ stehen, um
unerwartetes Verhalten beim Data Storage zwischen
Master und Gerät zu vermeiden.
3
2
Boolean
Local Parameterization
Lock
4
3
Boolean
Local User Interface
Lock