7--12
63
Use and maintenance manual
PH211
"
Slacken the head locking lever, by gripping it from the operator side and pu-
shing it forwards.
"
Slacken the nut and, holding it firm with a hex wrench, adjust the stop screw
until the right angle error shown on the goniometer is corrected.
"
Retighten the nut to lock the stop screw in the correct position.
"
Finally, lock turntable and head rotation by pulling the locking lever back to-
wards you.
To
adjust the 45
˚
and 60
˚
fixed points, you will need a workshop goniometer
or an instrument that can measure the exact angle of the blade.
Warning
Содержание PH 211
Страница 1: ...EN YEAR OF MANUFACTURE ______________ PH 211 USE AND MAINTENANCE MANUAL ...
Страница 2: ......
Страница 6: ......
Страница 40: ...6 2 34 Use and maintenance manual PH211 Standardised Wiring Diagrams HB single phase ...
Страница 41: ...6 3 35 Diagrams exploded views and replace Standardised Wiring Diagrams three phase ...
Страница 44: ...6 6 38 Use and maintenance manual PH211 Motor assembly Handle assembly ...
Страница 46: ...6 8 40 Use and maintenance manual PH211 Blade adjustable assembly rear Blade adjustable assembly front ...
Страница 48: ...6 10 42 Use and maintenance manual PH211 Idler wheel and Drive wheel assembly Blade back cover assembly ...
Страница 50: ...6 12 44 Use and maintenance manual PH211 Control panel assembly ...
Страница 52: ...6 14 46 Use and maintenance manual PH211 Base assembly ...
Страница 54: ...6 16 48 Use and maintenance manual PH211 Vise assembly A Vise assembly B PH 211 ...
Страница 56: ...6 18 50 Use and maintenance manual PH211 Stand leg assembly ...
Страница 58: ......
Страница 72: ......
Страница 97: ......
Страница 98: ......