6
Oil Types
The HYCON power packs use standard hydraulic oil, i.e. all types of mineral oil and
biodegradable oil, which comply with the following values:
Ambient temperature range
Below 10°C
50°F
10 … 30°C
50 … 68°F
Above 30°C
68°F
Recommended oil viscosity grade
VG 32
VG 46
VG 68
Recommended oil cleanliness
ISO 4406 /19/16 / NAS 1638 10
Permitted viscosity
cSt
10 – 600
Viscosity index
Minimum
100
Oil temperature area
°C /°F
-20 to 70 / -4 to 158