Installation and Maintenance Manual
30
Description of Functions Available in the User Menu
User 1
[Ct _]
Close timer setting:
This menu item is the automatic close timer for the gate. The factory
setting is zero, which is off. It may be configured up to 99 seconds.
User 2
[hC 0]
Momentary Close:
This menu item is to configure for the system for constant hold push
button Close function. The factory setting is zero, which is momentary contact input.
User 3
[ho 0]
Momentary Open:
This menu item is to configure for the system for constant hold push
button Open function. The factory setting is zero, which is momentary contact input.
User 4
[AP 0]
Power loss function:
This menu item only appears if the operator is a DC battery powered
version. This item is to configure what gate function will occur when the AC power fails.
User 5
[ro 0]
Radio control option:
This menu item is to configure whether a radio input can open only
(default) or if set to 1, also has the ability to close the gate when it is fully open.
User 6
[bF 2]
Warn before operate:
This menu item controls the warn before operate buzzer and can be
configured three ways. Setting the menu item to zero turns the buzzer off, but we strongly advise leaving this
valuable warning feature active to alert prior to gate motion.
Never cut the wires to the buzzer or unplug it
.
Set to 1 and the buzzer will sound three seconds before motion and the entire time during gate motion. Set to
2 (default) and the buzzer will sound three seconds before motion and for the first two seconds of motion.
User 7
[FA 0]
Forced open Alert and automatic gate reposition:
This function is intended for highly
secure facilities. If it is enabled, by setting the selection to 1, it will reinitiate a closure if a gate is somehow
forced to open far enough that the close limit switch releases. The Alert buzzer will sound immediately, even
if it had been turned off, and the motor will restart to secure the gate fully closed. If the gate is not fully closed
within four seconds the motor turns off and the alert buzzer sounds an intruder alert for thirty seconds. The
LCD display reads ALE1.
User 8
[dA 0]
Drift Closed Alert and automatic gate reposition:
If it is enabled, by setting the selection
to 1, it will restore a gate to back its fully open position if it drifts closed for any reason. The buzzer will sound
a warn before operate alert, even if it had been turned off, and the motor will restart to reopen the gate. The
motor will run for a maximum of four seconds and if the gate is not fully open in this period, the buzzer sounds
for ten seconds and the LCD display reads ALE2.
User 9
[PE 0]
PE Alignment Mode:
This feature may be activated as an aide to photo-eye emitter /
receiver alignment. The buzzer chirps once as the photo eye is triggered or twice when the photo eye is
released. The Alignment Mode is cancelled with any close limit input or reset input.
User 10
[CL 0]
Clock and date set:
The Smart Touch Controller is equipped with a 24 hour 365 day clock,
so that events of significance can be logged and stamped with the time and date. This feature is useful to
record historical operation data, which can be accessed via the RS232 port.
User 11
[Ld 5]
LCD Contrast set:
Under some extreme high or low temperature conditions, it may be
necessary to adjust the contrast of the LCD display. The display is adjustable from 0-9 with a factory default
setting of 5.
User 12
[dD 0]
Extended Data Log:
When set to 1 the ST Controller logs additional events within the Smart
Touch Controller in addition to the normal error and alert logs. This parameter resets to 0 automatically after
24 hours
– (Requires New Generation Smart Touch board and V4.xx software)
Содержание SwingRiser 14
Страница 2: ......
Страница 18: ...Installation and Maintenance Manual 8 Tools Required for an Efficient Installation ...
Страница 19: ...Installation and Maintenance Manual 9 Swing Gate Post Details ...
Страница 20: ...Installation and Maintenance Manual 10 Swing Gate Post Details continued ...
Страница 21: ...Installation and Maintenance Manual 11 Swing Gate Post Details continued ...
Страница 22: ...Installation and Maintenance Manual 12 HRG 220 Pump Pack ...
Страница 23: ...Installation and Maintenance Manual 13 HRG 222 Pump Pack ...
Страница 24: ...Installation and Maintenance Manual 14 How Our Hydraulic Swing Gates Work ...
Страница 32: ...Installation and Maintenance Manual 22 ...
Страница 36: ...Installation and Maintenance Manual 26 New Generation Smart Touch Board Runs software 4 xx and higher ...
Страница 54: ...Installation and Maintenance Manual 44 Loop Layouts ...
Страница 77: ...Installation and Maintenance Manual 67 ...
Страница 83: ...Installation and Maintenance Manual 73 Smart Touch Controller Connections ...
Страница 84: ...Installation and Maintenance Manual 74 ...