Only qualified personnel should perform this welding machine.
Wear protective garments such as gloves, heavy shirts, trousers and high shoes according to the related
safety precautions.
Power off immediately if the abnormal indicator on, then check the input voltage, cooling fan motor, or if
there is lack-phase or overheat. Then turn on the machine again when it cooled down, if still have problem,
please contact Huayuan company.
8. Operations
8.1 Front panel instruction
1. Digital meter
2. Current/voltage select switch
3. Power indicator
4. Overload indicator
5. Lack voltage indicator
6. Hot current adjust knob
7. Arc force current adjust knob
8. Welding current adjust knob
9. Remote/local control select switch
10. Remote control connector
8.2 operating instruction
When the machine energized, the green indicator on the front panel on, the current/voltage select switch
indicate the voltage value about 80V, the welding machine is ready to work.
1. Local control adjust