ZX7-315/400/500/630IGBT OPERATOR’S MANUAL
- 11 -
Suddenly there is no welding
current during the welding
process
1.welding cable and work piece
with poor connection
2.Protective fuse break
1.check the weld cable
2.Replace the fuse(1.5A)
Machine not work, but the
overload indicator on
1. Cooling fan damaged cause
overheat protection
2. Over-load use cause over heat
protection
1. Replace cooling fan
2. Stop welding, let the machine
operate for 10min without load
Machine not work, but the lack
voltage indicator on
The input lack-phase or lack voltage
Check three phase input
Attention
: Only qualified technicians should perform troubleshooting work on the machine. If for any
reason you do not understand the test procedures or are unable to perform the tests/repairs safely, please
contact us for technical assistance.
11 Packing List
1. ZX7-IGBT welding machine
1 set
2 . Electrode holder
1 pcs
3. Fast connector
2 pcs
4..Documents (Guarantee card, operatoer's manual, quality certificate)
1 for each