1. Main usage and application range

1.1 Main usage

ZX7–IGBT Series welding machine can be used for different types of electrode, especially suitable for
hydrogen electrode to weld low carbon steel, mid-carbon steel and their alloy workpiece. It is mainly used
in the industries like ship-building, boiler, power tower, petroleum and construction industries.
ZX7-630IGBT is also suitable for air carbon arc gouging.
ZX7-IGBT series is one of our newest energy-saving power source, which with excellent technical standard
and welding craft. Its advantages as:
●Good dynamic characteristic, stable arc, good performance, little spatter
●Wide distribution voltage: 380VAC±60VAC
● Arc force adjust function
●Hot current adjust function
●Welding current preset function
● Easy to operate, with remote control connector
● Lack voltage, over heat protection function
● Input voltage fluctuation compensation function, keep stable output current
● High efficiency, Low non-load loss
●Small volume, light weight, easy to move

1.2 Model specification

This welding machine designed and produced according to the GB15579.1-2004

JB/T7824-1995.

Model: Z X 7 — ×××IGBT

Insulated bipolar transistor
Rated welding current
Invert
Slope-control
Rectified arc welding machine

Note: if there is a "Q

in the rear of the model name, this indicate the fibrin welding machine, the operation

method the same as the ZX7-IGBT machines, which specially suitable for fibrin electrode.

2. Working Environment

1. Environmental area

1.1 Operating altitudes: less than 1000m
1.2 Temperature ranges:
Operating temperature range: -10

~+40

Storage temperature range: -25

~+55

1.3 Relative humidity: 50% for temperature up to 40

90%@20

1.4 Do not locate where there is harmful gases, chemical depositions, mycete, and other explosive or
corrosive substances, prevent shaking and jolt.
1.5 Keep the machine inside and dry all the times, do not place it in a confined space, do not locate where
the machine is exposed to direct sunlight.

Содержание ZX7-315IGBT

Страница 1: ...ZX7 315 400 500 630IGBT OPERATOR S MANUAL 1 ZX7 315 400 500 630IGBT INVERTER DC ARC WELDING MACHINE OPERATOR S MANUAL PLEASE READ CAREFELLY BEFORE OPERATING CHENGDU HUAYUAN ELETRIC EQUIPMENT CO LTD ...

Страница 2: ...Make certain the insulation is large enough to cover your full area of physical contact with work and ground c Always be sure the work cable makes a good electrical connection with the metal being welded The connection should be as close as possible to the area being welded d Ground the work or metal to be welded to a good electrical earth ground e Maintain the electrode holder work clamp welding ...

Страница 3: ...e been taken to insure that such procedures will not cause flammable or toxic vapors from substances inside They can cause an explosion even though they have been cleaned e Vent hollow castings or containers before heating cutting or welding They may explode f Sparks and spatter are thrown from the welding arc Wear oil free protective garments such as leather gloves heavy shirt cuffless trousers h...

Страница 4: ...n Usage and Application Range 5 Working Environment 5 Technical Specifications 6 Hardware Overview 7 General Description 7 Delivery and Storage 8 Installation and Adjustment 8 Operation 9 Maintenance 10 Troubleshooting 10 Packing List 11 Wiring Diagrams 12 ...

Страница 5: ...ltage fluctuation compensation function keep stable output current High efficiency Low non load loss Small volume light weight easy to move 1 2 Model specification This welding machine designed and produced according to the GB15579 1 2004 JB T7824 1995 Model Z X 7 IGBT Insulated bipolar transistor Rated welding current Invert Slope control Rectified arc welding machine Note if there is a Q in the ...

Страница 6: ...7 630IGBT Input power Three phase 380V 15 50 60HZ Rated input capacity KVA 13 8 19 7 26 3 36 2 Rated input current A 21 30 40 55 Open circuit voltage V 74 77 80 Rated welding current A 315 400 500 630 Rated welding voltage V 32 6 36 40 44 Rated duty cycle 60 Current range A 20 315 30 400 40 500 50 630 Weight kg 35 38 42 43 Dimension L W H mm 570 290 530 640 290 530 Rated duty cycle 60 means take 1...

Страница 7: ...reactor the HF current will change to the low voltage but high welding current The control circuit will control the output current through the adjusting of the pulse width The negative feedback signal which is the real welding current get from the output current sensor put into the special PWM circuit after compared with the current adjust signal then output the driving pulse to control the IGBT s...

Страница 8: ...wire CSA should no less than the following table 7 3 Requirements table Parameter Model CSA for input copper wire mm2 Breaker capacity A Fuse protector A CSA for ground lead cable mm2 ZX7 315IGBT 4 40 20 4 ZX7 400IGBT 4 40 32 4 ZX7 500IGBT 6 60 40 6 ZX7 630IGBT 6 60 50 6 Warning Completely read the operator s manual before installation strictly follow the installation requirements The 3 phase inpu...

Страница 9: ...it cooled down if still have problem please contact Huayuan company 8 Operations 8 1 Front panel instruction 1 Digital meter 2 Current voltage select switch 3 Power indicator 4 Overload indicator 5 Lack voltage indicator 6 Hot current adjust knob 7 Arc force current adjust knob 8 Welding current adjust knob 9 Remote local control select switch 10 Remote control connector 8 2 operating instruction ...

Страница 10: ...mplete welding Usually for the average current welding the arc force current can decrease even to zero so that it can reduce spatter 4 Hot current adjust When use small current welding properly adjust the hot current can increase the arc striking success ratio 9 Maintenance Install and operate the machine strictly according to the operator s manual the warranty period is one year 10 Troubleshootin...

Страница 11: ...an 2 Stop welding let the machine operate for 10min without load Machine not work but the lack voltage indicator on The input lack phase or lack voltage Check three phase input Attention Only qualified technicians should perform troubleshooting work on the machine If for any reason you do not understand the test procedures or are unable to perform the tests repairs safely please contact us for tec...

Страница 12: ...ZX7 315 400 500 630IGBT OPERATOR S MANUAL 12 ...

Отзывы: