LGK-40/63IGBT OPERATOR’S MANUAL
8
Rated input voltage
3
~
50Hz
380V
Rated input capability
6.0KVA
9.9KVA
Open circuit voltage
222VDC
260VDC
Rated output current
40A
63A
Current adjusting range
20
~
40A
30
~
63A
Rated output voltage
96V
105.2V
Rated duty cycle
60%
60%
Insulation level
F
F
Quality cutting thickness
(
steel
)
0.1
~
7mm
0.1
~
12mm
Max cutting thickness
(
steel
)
12mm
20mm
Applied plasma air
Compressed air
Compressed air
Cooling model
Air-cooling
Air-cooling
Dimension(L×W×H)
585×280×485mm
800×380×610mm
Weight
25Kg
26Kg
Shell shield rank
IP21S
2
.
Plasma gas conditions
Work pressure range
:
0.3MPa
~
0.5MPa
Gas supply pipe compression strength
:
≥1MPa
Gas supply pipe inner dimension
:
≥Φ8
Gas supply flux
:
≥40L/min
Filter water from gas and then put it into cutter
Figure 1 External characteristic
◆
Work principles
The control circuit of cutting machine adopts advanced electronic part IGBT as the main inverter
switch component. Three-phase AC power is converted to 20KHz high-frequency DC current after
being rectified by three phase rectifier. Then under the function of IGBT inverter the DC current is
inverted to AC high frequency current, which is inverted to DC current after experiencing voltage
reduction in high frequency transformer, current rectifying in fast recovery diode. This DC current is
filtered through reactor, and the output cutting current is obtained. Control circuit can control output
current by controlling driven pulse width. The real time cutting current, which is obtained through
I
U
270V
240V
40A
63A
63A/105.2V
40A/96V
Содержание LGK-40/63IGBT