The phase shifter has the characteristics of easy operation, small size,

low noise and good output waveform, whith is able to meet the test and

calibration for high AC power and phase of single or three phases, phase and

other, and can also be used among test device of meter.

. MAIN TECHNOLOGY INDICATORS

1.Input voltage

Three-phase four-wire 3×380(220)V

50Hz

2.Output Voltage

Three-phase four-wire 3×(0~380) / (0~220)

Three and a

half figures display, accuracy: 1.0grade

Output current: AC 0-20A Three and a half figures display, accuracy:

1.0grade

3.Maximum output capacity 3×300VA

4.Rough tune of three phase: 0° ~ 360°, 30° to phase shift of each step

5.fine tune for three phase: -3° ~ 18°, 12° ~ 33°, four figures display, accuracy:

0.5grade

6. Voltage fluctuation: rough tune ≤ 1.5%, fine tune ≤ 2.0%

7.Waveform distortion: distortion of input waveform ≤ distortion of output

waveform

8.Increasing of temperature:

60

9. Insulation resistance: ≥ 22MΩ

10.Pressure test: 1.5kV/min

11.Environment: temperature -10

~ 40

, humidity

80%

Содержание HTYX-III

Страница 1: ...find the changes in the appendix Sorry for the inconvenience If you have further questions welcome to contact with our service department The input output terminals and the test column may bring volt...

Страница 2: ...e In order to avoid possible danger this product can only be used within the prescribed scope Only qualified technician can carry out maintenance or repair work To avoid fire and personal injury Use P...

Страница 3: ...ngs Do Not Operate without Covers Do not operate this product when covers or panels removed Use Proper Fuse Only use the fuse with type and rating specified for the product Avoid Touching Bare Circuit...

Страница 4: ...Security Terms Warning indicates that death or severe personal injury may result if proper precautions are not taken Caution indicates that property damage may result if proper precautions are not tak...

Страница 5: ...5 Contents OUTLINE 6 APPLICATION AND APPLIED SCOPE 6 MAIN TECHNOLOGY INDICATORS 7 FUNDAMENTAL THEORY 8 HOW TO USE 8 NOTES 11 MAINTENANCE 12 TRANSPORT AND STORAGE 13...

Страница 6: ...d reliable sealed and easy to carry or to use in the field and on site APPLICATION AND APPLIED SCOPE Phase shifter can reach any point of the lead or lag phase shift from 0 to 360 degrees The phase sh...

Страница 7: ...r wire 3 0 380 0 220 Three and a half figures display accuracy 1 0grade Output current AC 0 20A Three and a half figures display accuracy 1 0grade 3 Maximum output capacity 3 300VA 4 Rough tune of thr...

Страница 8: ...shift please exchange the sequence of any input three phase FUNDAMENTAL THEORY This phase shifter is designed amd maded by the theory of transformer phase shift and the fundamental theory is explaine...

Страница 9: ...t button of phase display Press the key to display the phase angle A6 Latch button of phase display With no change of phase we can press the key to lock the number A7 Power switch this key can be pres...

Страница 10: ...nding columns of input three phases and four wires B2 Ground column of the chassis B3 F1 F2 F3 buttons are respectively corresponding to the insurance block of C B A phases B4 Binding columns of outpu...

Страница 11: ...tion switch A9 when the switch is up adjust A11 clockwisely for one loop and the phase shift is 15 when the switch is down adjust A11 Counterclockwisely for one loop and the phase shift is 15 After ad...

Страница 12: ...ear Among the warranty period it is free to repair the machine because of quality and technical problems and we provide preferential services caused by careless handling MAINTENANCE 1 Verify the avail...

Страница 13: ...aterials in order to avoid unnecessary damage during transit and causing unnecessary losses to you It is not allowed stacking emission without wooden box during transit The maximum packing stacking la...

Отзывы: