10
current function, the machine gives the output of AC current range from 0~20
A, witch lead to the phase shift of iuput B source.
A9. Fine tune selection switch, choice of two range: -3°~18°, 12°~33°.
A10. Adjustment button of output voltage, and the outputs of U,V,W phase are
adjusted simultaneousely by this button.The voltage display gives the voltage
of U,W phase range from 0~380V.
A11. Fine tune button, combined with A9 it can achieve the function of phase
shift in 30°.
B1.Binding columns of input three phases and four wires.
B2.Ground column of the chassis.
B3.F1, F2, F3 buttons are respectively corresponding to the insurance block of
C, B, A phases.
B4. Binding columns of output three phases and four wires.
B5. F4, F5, F6 buttons are respectively corresponding to the insurance block
of W, V, U phases.
B6. Binding column of output current.
(2) How to use
1. Check B3, B5 of the panel to insure the fuse is intact.
2. Cut off the power button and turn the the output voltage button A10 to the
lowest,then connect the input source of three phases and four wires A, B, C, O
on the panel B1.
3. Connect the neccesary load for output voltage of U, V, W, N phases on the