20
A. the end of junction box is opened to the ground and the
secondary wirings are vacant. Record should be made so as to
make it restored after the testing.
B. Turning on the switches of main power supply and internal
high-voltage allowable of dielectric loss tester.
C. Moving the cursor to the "Connection mode" and pressing
"ENT". Pressing "
" or "
", selecting "CV" and then pressing
"ESC".
D: Moving the cursor to "Measure voltage" and choosing 1KV
and pressing "ESC"; moving the cursor to "Start to measure",
pressing "ENT" and waiting for the display of results. If the results
need to be printed out, pressing "ENT".
(2) Measuring C1: the wiring is shown in Figure 14. The basic
operation is the same as that of measuring C2.
(3) Note: The C1 and C2 can only be measured under the
testing mode of CVT; CVT would be damaged in the methods of
positive connection and negative connection!