CVH8, HVH8, TVH8, VA9, HVA9, TVA9: APPLICATION GUIDELINE & SERVICE MANUAL
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
24
Variable Speed Drive LED Location and Description (Sizes 25, 36, 37, 48, 49 and 60)
A14329
NOTE
: If any of the AOC control board header pins are damaged or are not making good contact, AOC board should be replaced.
Table 11 – MOC LED Description (Sizes 25, 36, 37, 48, 49 AND 60)
Reference
Color
Status
Description
LD1
Red
Steady On
MOC powered where DC bus is 40volts or greater
Off
No power, capacitor voltage drained
LED1
Red
Steady On
DCF and board DC high voltage and discharge circuit powered on
Off
No power
LED3
Amber
Steady On
MOC board switching power supply to power AOC board on
Off
No Power
Blinking
Indicates communication from MOC to AOC
LD5
Green
Steady On
Indicates 5 volt connection status OK between AOC and MOC
Off
No Power
Table 12 – AOC LED Descriptions (Sizes 25, 36, 37, 48, 49 AND 60)
Reference
Color
Status
Description
STATUS
Amber
Steady On
AOC status - standby mode
Blinking
AOC function/fault status
COMM
Green
Steady On
Communication from AOC to indoor wall control
Table 13 – LED Not Functioning Properly- Requires AOC or Inverter Replacement
Reference
Color
Suspect AOC board
Failure Description
STATUS
Amber
If Amber STATUS light is not on (neither steady nor
blinking), with power to outdoor unit
AOC STATUS is not functioning properly and AOC board
should be replaced.
COMM
Green
In Communicating mode, if Green COMM LED is not on
when AB indoor wires are connected to AOC AB
connector and indoor has communications
AOC is not capable of communicating with indoor; AOC
board should be replaced.
Table 14 – Fault Codes requiring AOC or Inverter Replacement
Fault Code Description
Fault Flash Code
Failure Description
Communications Loss
179
Loss of communication with outdoor unit AOC board; AOC or Inverter may need to be replaced