How to adjust finishing size.
①
Load internal circle pattern(Ø 50).
②
Execute the beveled process and the rimless process for all types of lenses.
③
Check the size of processed lenses and input the adjustment value.
•
How to adjust polishing size
Add polishing option and proceed with the same step for adjusting finishing size.
•
How to input adjustment value (Flat edging without polishing, PL lens).
If the size of internal circle (Ø50) data is 52mm, input -1.0 for Finishing Size
Rimless
PL value.
•
Remember that the adjustment value is based on radius. (Do not confuse with the Frame
Fitting value. Frame Fitting value is based on diameter).
•
Adjust the value within the tolerance ±0.1mm.
!