#OSO-45 #OSO-60 R.2 January 2021
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
FACING AND FINISHING
15
3.0 FACING AND FINISHING
3.1 Facing and Finishing Requirements
3.1.1 Mantel Requirements
WARNING: All minimum clearances to combustible material MUST be
maintained.
•
Combustible Mantel Projections:
As referenced in Figure 3.1,
the 2" (51mm) mantel can start at 2-7/8" (73mm) above the
top of the viewing opening. Mantel projections can increase 2"
(51mm) of depth for every 1" (25mm) of height starting at the 2"
(51mm) mantel.
3.1.2 Finishing Requirements
•
This appliance is designed to accommodate finishing material up
to 5/8" (16mm) thick.
Figure 3.1, Mantel Clearances
4”
(102mm)
2”
(51mm)
5”
(127mm)
2
7⁄8
”
(73mm)
6” (152mm)
8” (203mm)
10” (254mm)
Top of viewing opening
Each square represents
1” (25mm)
of mantel projection
Nominal 2” x 4” framing used in framing