background image

3086855_C  

U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900 • www.hussmann.com

5-4

 

s

ErvIcE

 — t

EchnIcal

 D

ata

REPLACEMENT PARTS LIST

Description

Part

 

number

 

MPCETNM6S

MPCETNM6S

 

+

  

kit

 

US75

 

+

  

kit

 

UQ34

(220V

 

option)

(120V

 

option)

Distributor

2H01877505

X

X

Heat

 

Exchanger

00008480

X

X

Evaporator

  

050033700

X

X

Plastic

 

Collar

 

Fan

0409510

X

X

Fan

 

Blade

0428111

X

X

Evap

 

Fan

 

Motor

0477653000

X

X

Bracket

 

Evap

 

Fan

 

Motor

0552827

X

X

Sight

 

Glass

 

(Sporlan

 

SA

13S)

225010075

X

X

Drier

 

(Sporlan

 

C

163

S)

17S507

X

X

Condensing

 

Unit

 

Main

 

Switch

E205705

X

X

Evap

 

Pan

 

1500W

240V

1H95137550

X

Evap

 

Pan

 

1500W

120V

1H95136550

X

Relay

 

T92P7A22

240

1804241

X

Relay

 

T92P7A22

120

0459304

X

Pre

programmed

 

Controller

 

MPC

 

220V

3090830

X

Pre

programmed

 

Controller

 

MPC

 

120V

3072023

X

Power

 

Cord

 

L14

30P

0557599

X

Power

 

Cord

 

L5

30P

0557077

X

Description

MPCETNM6S

MPCETNM6S

Refrigeration

  

R404A

 

+

  

kit

 

US75

 

 

+

  

kit

 

UQ34

(220V

 

option)

(120V

 

option)

TXV

 

Valve

E205982

X

X

Condensing

 

Unit

 

(M6GP

H074

CAV

212)

3066464500

X

Condensing

 

Unit

 

(M6KP

0075

CAA

221)

3082672500

X

Description

MPCETNM6S

MPCETNM6S

Refrigeration

  

R448A

 

+

  

kit

 

US75

 

+

 

VI05

 

+

  

kit

 

UQ34

 

+

 

VI06

(220V

 

option)

(120V

 

option)

Condensing

 

Unit

 

(M6GP

H090

CAV

212)

3082678500

X

Condensing

 

Unit

 

(M6KP

0075

CAA

221)

3082672500

X

TXV

 

EGDE

1/3

C

 

3031930

X

X

Part

 

number

 

Part

 

number

 

5‐4

Standard Parts

Description

Part Number  MPCETNM6S

Front Plexiglass

3071582

X

Black End Trim

170301121

X

Caster

2H16163800

X

Drain Trap

18S279

X

Cover Drain

0301266

X

MPCETNM6S

MPCETNM6S

Refrigeration Parts

+ kit US75

+ kit UQ34

Description

Part Number  (220V option)

(120V option)

Distributor

2H01877505

X

X

TXV Valve

E205982

X

X

Heat Exchanger

00008480

X

X

Evaporator  

050033700

X

X

Plastic Collar Fan

0409510

X

X

Fan Blade

0428111

X

X

Evap Fan Motor

0477653000

X

X

Bracket Evap Fan Motor

0552827

X

X

Sight Glass (Sporlan SA‐13S)

225010075

X

X

Drier (Sporlan C‐163‐S)

17S507

X

X

Condensing Unit Main Switch

E205705

X

X

Condensing Unit (M6GP‐H074‐CAV‐212)

3066464500

X

Condensing Unit (M6KP‐0075‐CAA‐212)

3082672500

X

Evap Pan 1500W‐240V

1H95137550

X

Evap Pan 1500W‐120V

1H95136550

X

Relay T92P7A22‐240

1804241

X

Relay T92P7A22‐120

0459304

X

Pre-programmed Controller MPC 220V

3090830

X

Pre-programmed Controller MPC 120V

3072023

X

Power Cord L14‐30P

0557599

X

Power Cord L5‐30P

0557077

X

Sheet Metal / Replacement Painted Parts

Description

Part Number  MPCETNM6S

Air Deck Pan MPC

3071720

X

Bracket MPC Wire Rack

3071600

X

Display Assy‐Step 6 Levels

3072850

X

Model

Nominal HP

Refrigerant Type

Optional Kit

Volts

Nema Plug

Fuse Amp

Hz / Ph

60/1

L14‐30P

L5‐30P

208/230

115

UQ34

MPCETNM6S

3

/

4

R‐404a

30 Amps

US75

5‐4

Standard Parts

Description

Part Number  MPCETNM6S

Front Plexiglass

3071582

X

Black End Trim

170301121

X

Caster

2H16163800

X

Drain Trap

18S279

X

Cover Drain

0301266

X

MPCETNM6S

MPCETNM6S

Refrigeration Parts

+ kit US75

+ kit UQ34

Description

Part Number  (220V option)

(120V option)

Distributor

2H01877505

X

X

TXV Valve

E205982

X

X

Heat Exchanger

00008480

X

X

Evaporator  

050033700

X

X

Plastic Collar Fan

0409510

X

X

Fan Blade

0428111

X

X

Evap Fan Motor

0477653000

X

X

Bracket Evap Fan Motor

0552827

X

X

Sight Glass (Sporlan SA‐13S)

225010075

X

X

Drier (Sporlan C‐163‐S)

17S507

X

X

Condensing Unit Main Switch

E205705

X

X

Condensing Unit (M6GP‐H074‐CAV‐212)

3066464500

X

Condensing Unit (M6KP‐0075‐CAA‐212)

3082672500

X

Evap Pan 1500W‐240V

1H95137550

X

Evap Pan 1500W‐120V

1H95136550

X

Relay T92P7A22‐240

1804241

X

Relay T92P7A22‐120

0459304

X

Pre-programmed Controller MPC 220V

3090830

X

Pre-programmed Controller MPC 120V

3072023

X

Power Cord L14‐30P

0557599

X

Power Cord L5‐30P

0557077

X

Sheet Metal / Replacement Painted Parts

Description

Part Number  MPCETNM6S

Air Deck Pan MPC

3071720

X

Bracket MPC Wire Rack

3071600

X

Display Assy‐Step 6 Levels

3072850

X

Model

Nominal HP

Refrigerant Type

Optional Kit

Volts

Nema Plug

Fuse Amp

Hz / Ph

60/1

L14‐30P

L5‐30P

208/230

115

UQ34

MPCETNM6S

3

/

4

R‐404a

30 Amps

US75

Содержание MPCETNM6S

Страница 1: ...MPCETNM6S Mobile Produce Case Self Contained Installation Operation Manual P N 3086855_C October 2019 IMPORTANT Keep in store for future reference MANUAL I O MPCETNM6S Spanish 3087332...

Страница 2: ......

Страница 3: ...ORTANT KEEP IN STORE FOR FUTURE REFERENCE Quality that sets industry standards 12999 St Charles Rock Road Bridgeton MO 63044 2483 U S Canada 1 800 922 1919 Mexico 1 800 890 2900 www hussmann com 2019...

Страница 4: ...ater Seal 2 2 START UP OPERATION Controller Operation 3 1 Display Buttons 3 1 Defrost Alarms 3 2 Digital On Off Signals 3 2 Data Communication 3 3 Data Specifications 3 4 Control Sensor Configuration...

Страница 5: ...oided could result in damage to equipment P N 3086855_C U S Canada 1 800 922 1919 Mexico 1 800 890 2900 www hussmann com This warning does not mean that Hussmann products will cause cancer or reproduc...

Страница 6: ...NDENSING UNIT AND EVAPORATIVE PANS REFRIG Hz Ph Volts RLA VOLTS AMPS WATTS R 404A 60 1 208 230 6 8 240 6 3 1500 R 404A 60 1 115 15 0 120 12 5 1500 OPTIONAL HIGH OUTPUT LED LIGHTS 115 VOLT AMPS WATTS A...

Страница 7: ...ld be thoroughly examined for shipping damage before and during unloading This equipment has been carefully inspected at our factory Any claim for loss or damage must be made to the carrier The carrie...

Страница 8: ...the life of the product Be sure to position self contained merchandisers properly SELF CONTAINED models have vented base panels to allow air circulation through the condensing unit Allow for a minimum...

Страница 9: ...a person Do not place heavy objects on the merchandiser SHIPPING SKID Each merchandiser is shipped on a skid to protect the merchandiser s base and to make positioning the case easier Remove the top...

Страница 10: ...nage of defrost water SERIAL PLATE LOCATION The serial plate is located on the inside of the merchandiser s display area as shown below REFRIGERATION UNIT ACCESS The rear panel may be removed by lifti...

Страница 11: ...cord 6 Ensure that the proper electrical requirements for the equipment are supplied 7 Verify field electrical connections are tight 8 Verify all electrical wiring is secured and clear of any sharp ed...

Страница 12: ...1 6 Installation P N 3086855_C U S Canada 1 800 922 1919 Mexico 1 800 890 2900 www hussmann com NOTES...

Страница 13: ...ways use a dedicated circuit with the amperage stated on the unit Plug into an outlet designed for the plug Do not overload the circuit Do not use long or thin extension cords Never use adapters If in...

Страница 14: ...f not air flow from the condenser will be directed over the evaporator pan and defrost water in the pan may overflow Refrigeration lines are under pressure Refrigerant must be recovered before attempt...

Страница 15: ...odes Find the parameter code you want to change and push the middle buttons until value for the parameter is shown When you have changed the value save the new value by once more pushing the middle bu...

Страница 16: ...ion with reference displacement r39 Lower alarm limit Here you set when the alarm for low tempera ture is to start The limit value is set in C abso lute value The limit value will also be raised in co...

Страница 17: ...relay cuts in when rail heat is to operate Light The relay cuts in when the light has to be switched on Hotgas defrost See dia gram The relay will cut out when defrost has to be done Data communicati...

Страница 18: ...3 4 Start up Operation P N 3086855_C U S Canada 1 800 922 1919 Mexico 1 800 890 2900 www hussmann com...

Страница 19: ...3086855_C 3 5 HUSSMANN CORPORATION BRIDGETON MO 63044 2483 U S A MPCETNM6S Control Sensor Configuration DISCHARGE AIR SENSOR DEFROST SENSOR...

Страница 20: ...commended performance TEV ADJUSTMENT Expansion valves may be adjusted to fully feed the evaporator Before attempting to adjust valves make sure the evaporator is clear or only lightly covered with fro...

Страница 21: ...ays bring the oldest product to the top and set the newest to the bottom Air discharge and return flues must remain open and free of obstruction at all times to provide proper refrigeration and air cu...

Страница 22: ...tion of merchandiser 2 Apply power to the merchandiser Be sure switch is in ON position 3 Wait for Danfoss AK CC 210 to start up During start up wait for indicators for the evaporator fans refrigerati...

Страница 23: ...sed cleaners on acrylic parts Solvent oil or acidic based cleaners on any interior surfaces Do not use high pressure water hoses Do Remove the product and all loose debris to avoid clogging the waste...

Страница 24: ...d be cleaned every six months Dirty louvers will cause mer chandisers to perform poorly The louvers may be cleaned with a vacuum cleaner Soap and water may be used if all water is removed from the lou...

Страница 25: ...CLEANING COILS Condenser coils should be cleaned at least once per month Additional cleaning may be needed depending on the operational environ ment A dirty condenser blocks normal airflow through the...

Страница 26: ...atures CLEANING EVAPORATION PAN SELF CONTAINED ONLY The condensate water outlet for self contained models empties into a limited capacity evaporation pan Debris or dirt accumulation inside the conden...

Страница 27: ...t and air registers fans and doors etc x Check for water leaks x Clean evaporator coil s and fan blade s Do not use an acid base cleaner Rinse off any cleaner residue x Clean discharge air honeycombs...

Страница 28: ...4 6 Maintenance P N 3086855_C U S Canada 1 800 922 1919 Mexico 1 800 890 2900 www hussmann com NOTES...

Страница 29: ...Lower fan plenum 8 Reconnect fan to wiring harness 9 Turn on power 10 Verify that motor is working and blade is turning in the correct direction 11 Close air gaps under fan plenum Warmer air moving in...

Страница 30: ...ear wa FOR PROMPT SERVICE When contacting the factory regarding problems be sure to have the Case Model and Serial Number handy This information is on a plate located on the case itself LOCK OUT TAG O...

Страница 31: ...liable electrical power supply to the equipment Check shelf loading Overstocking will adversely affect case performance If frost is collecting on fixture or product verify that store Humidity Control...

Страница 32: ...S 17S507 X X Condensing Unit Main Switch E205705 X X Condensing Unit M6GP H074 CAV 212 3066464500 X Condensing Unit M6KP 0075 CAA 212 3082672500 X Evap Pan 1500W 240V 1H95137550 X Evap Pan 1500W 120V...

Страница 33: ...ION ELECTRICAL BOX EVAPORATION PAN COMPRESSOR CONDENSER AIR INTAKE 22 188 4 500 18 750 18 750 24 438 120 V ELECTRICAL HARNESS MPCETNM6S PLAN VIEWS 24 438 18 750 18 750 22 188 4 500 WASTE OUTLET ELECTR...

Страница 34: ...S Canada 1 800 922 1919 Mexico 1 800 890 2900 www hussmann com 5 6 Service Technical Data MPCETNM6S CROSS SECTION Dimensions shown as inches 23 499 34 917 18 402 43 423 3 750 4 875 51 125 895 35 000 2...

Страница 35: ...g Unit hp 1 2 1 2 3 4 1 2 3 4 Condensing Unit Capacity 3620 4750 6090 4 010 6 090 9 3 BTU hr at std Rating conditions DEFROST DATA Frequency hr Offtime Failsafe minutes Defrost Termination Temperature...

Страница 36: ...890 2900 www hussmann com 5 8 Service Technical Data ESTIMATED SHIPPING WEIGHT Case Actual weights will vary according to optional kits included ma Plug Fuse Amp Hz Ph 5 30P 30A 4 30P with shipping c...

Страница 37: ...TCH FUSE BK W 3071849_B BL R R GR BK R R W BK BK R SWITCH S3 S1 S2 S4 UNIT CONDENSER NEMA L14 30 P 240V 60HZ 1HP W EVAPORATOR PAN FLOAT SWITCH SAFETY SWITCH BK CANOPY LED BK R Y W WARNING UNPLUG THE U...

Страница 38: ...SWITCH FUSE BK W 3083504_A BL R R GR BK W W W BK BK R SWITCH S3 S1 S2 S4 UNIT CONDENSER NEMA L5 30 P 115V 60HZ 1HP W EVAPORATOR PAN FLOAT SWITCH SAFETY SWITCH BK CANOPY LED BK R Y W WARNING UNPLUG THE...

Страница 39: ...information or other support contact your Hussmann representative Please include the model and serial number of the product Hussmann Corporation Corporate Headquarters Bridgeton Missouri U S A 63044 2...

Страница 40: ...Hussmann Corporation 12999 St Charles Rock Road Bridgeton MO 63044 2483 www hussmann com...

Отзывы: