HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 (Printed in U.S.A.)
REPLACING EVAPORATOR FAN
MOTORS AND BLADES
Refer to the data sheet shipped with each mer-
chandiser to determine location of evaporator
fans. Should it ever be necessary to service or
replace the fan motors or blades, be certain that
the fan blades are re-installed correctly.
T
HE
BLADES
MUST
BE
INSTALLED
WITH
RAISED
EMBOSSING
(
PART NUMBER ON BLADES
)
POSI
-
TIONED AS INDICATED ON THE PARTS LIST OF THE
DATA SHEET
.
For access to these fans:
1. Turn off power to the merchandiser.
2. Remove wire racks and bottom display pans.
3.
Disconnect fan motor from wiring harness.
4. Remove 6 screws attaching fan assembly to
plenum. Lift fan assembly out of plenum.
5. Remove nut, fan blade, and gasket.
6. Remove screws holding bottom of motor to
bracket.
(See next page for location of replaceable parts.)
Always disconnect the electrical power at the
main disconnect when servicing or replacing
any electrical component. This includes, but
is not limited to, such items as fans, heaters,
thermostats and lights.
WARNING
!
Gasket
Fan Blade
Nut
Motor
Lock Nut
Tool
Screws
Motor
Bracket
Tape
Bushing
Fan
Assembly
Screw
Power Cord
Chain
Hook
Plug