3-10
S
TARTUP
/ O
PERATION
P/N 3141959_C
U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900 • www.hussmann.com
The controller controls refrigeration temperature
and is factory installed inside the control panel .
Adjust the control to maintain the discharge
air temperature shown above . Measure dis-
charge air temperatures at the center of the
discharge louver .
Defrosts are time initiated and temperature
terminated for self-contained models . The defrost
settings are factory set as shown above .
To ensure a thorough defrost, defrost must be
terminated by the temperature termination
setting — not by time .
Refrigeration Controls
Defrost Controls
Notes:
The cases are pre programmed with
AP2 as default, which is low temp
frozen food application .
If the customer needs Medium temp
application, the default settings are to
comply with NSF 7 Type 1 .
Model
Application
Product Application
Discharge Air Temperature
Tripping
Dif ( ° F )
Controller
Set Point ( ° F )
Defrost Frequency
( per day )
Type of
Defrost
Temp.
Termination
Failsafe
Time ( min )
AP1
Med Temp - DOE
25 ° F to 43 °F ( -4 °C to 6 °C )
18
24 to
25
° F ( -4 to -3 ° C )
45 ° F ( 7 ° C )
**AP1
Med Temp - NSF 7 Type 1
20 ° F to 38 °F ( -6 ° C to 3 °C )
18
18 to
20
° F ( -7 to -6 ° C )
45 ° F ( 7 ° C )
**AP2
Frozen Food - DOE
´-19 to -9 ° F (-28 to -22 ° C )
10
´-20 to
-19
° F ( -29 to -28 ° C )
38 ° F ( 3 ° C )
AP1
Med Temp - DOE
22 ° F to 46 ° F ( -5 °C to 8 °C )
24
21 to
22
° F ( -6 to -5 ° C )
45 ° F ( 7 ° C )
**AP1
Med Temp - NSF 7 Type 1 16 ° F to 40 ° F ( -8 ° C to 4 °C )
24
15 to
16
° F ( -9 to -8 ° C )
45 ° F ( 7 ° C )
**AP2
Frozen Food - DOE
´-19 to -9 ° F (-28 to -22 ° C )
10
´-20 to
-19
° F ( -29 to -28 ° C )
38 ° F ( 3 ° C )
AP1
Med Temp - DOE
26 ° F to 44 ° F ( -3 °C to 7 °C)
18
24 to
26 °
F ( -4 to -3 ° C )
45 ° F ( 7 ° C )
**AP1
Med Temp - NSF 7 Type 1
20 ° F to 38 °F ( -6 ° C to 3 °C )
18
18 to
20
° F ( -7 to -6 ° C )
45 ° F ( 7 ° C )
**AP2
Frozen Food - DOE
´-19 to -9 ° F (-28 to -22 ° C )
10
´-17 to
-16
° F ( -27 to -26 ° C )
38 ° F ( 3 ° C )
FNGSC4A
3
50
Hotgas
FNGSC6A
3
50
50
FNGSC8A
3
Controls and Adjustments
Example of FNGSC8A (Medium Temp.)
Example of FNGSC8A (Low Temp.)