REFRIGERATION SYSTEM
FUNCTIONALITY
These cases can be used for medium or low
temperature applications and comply with
NSF 7 for medium temperature applications
and frozen food . FNGSC-A models are
self-contained and have a controller that
automates the refrigeration cycle and the
defrost cycle .
During refrigeration mode, the discharge line
solenoid valves (RSV1, RSV2) are energized
and held open, allowing the gas to flow
through each condenser .
Once the refrigerant is in a liquid, a capillary
tube is used as an expansion device that feeds
each evaporator . The darker arrows and
lines (left side) show the refrigerant direction
through circuit #1, and the lighter arrows and
lines (right side) show the refrigerant direction
of circuit #2 .
During refrigeration mode, hot gas solenoid
valves, (HGSV1, HGSV2) are deenergized and
(closed) .
System Diagram
-
Refrigeration Mode (FNGSC8A)