3-6
S
TARTUP
/ O
PERATION
P/N 3141959_C
U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900 • www.hussmann.com
SETPOINT: SETTING AND EDIT LOCK
To display the Setpoint value, press the
set
key to enter the “Machine Status” menu, then press the
set
key again when the “SEt”
label is displayed.
The Setpoint value appears on the display. To change the Setpoint value, press the
and
keys within 15 seconds.
Press
set
to confirm the modification.
set
set
set
It is possible to disable the keypad on this device.
The keypad can be locked by programming the “LOC” parameter appropriately.
With the keypad locked, you can still access the “Machine Status” menu by pressing
set
to display the Setpoint, but you cannot edit
it. To disable the keypad lock, repeat the locking procedure.
DISPLAY PROBES VALUE
To display the value read by probes connected to the device, press the
set
key and enter the “Machine Status” menu, then press
the key again when one of the probe-related labels “Pb1...Pb5” press the
set
key again. The value measured by the associated
probe will appear on the display.
NOTE
: The displayed value is read-only and cannot be modified.
KDEPLUS BUTTONS
The
KDEPlus
keyboard has 4 keys, as shown in the illustration:
1
2
3
4
Increases
set
STANDBY or ESC
DOWN
SET
UP
set
set
set
set
set
set
set
set
set
KEY-ACTIVATED FUNCTIONS
All models have the
UP
key set to enable the “Manual Defrost” function.
The DOWN and ESC keys can also be set to activate any other function required by the user.
The parameters for configuring the two keys are:
• H11
= DOWN key configuration
• H33
= ESC key configuration
The values that can be set apply to both keys and the functions that can be activated are:
H32/H33 value
Function to enable
0
disabled
1
defrost
2
reduced set
3
Light
4
Energy saving
5
AUX
6
Stand-by
7
Deep cooling cycle
8
Start/end defrost