REFRIGERATION DATA
Note:
This data is based on store temperature and
humidity that does not exceed 75
°
F and 55% R.H.
FF
Discharge Air (°F)
–12
Evaporator(°F)
–20
Unit Sizing (°F)
–23
Btu/hr/ft
FF
Parallel
535
Conventional
560
DEFROST DATA
FF
Frequency
(hr)
24
Defrost Water
(lb/ft/day)
1.0
(± 15%
based on case configuration and product
loading).
E
LECTRIC
FF
Temp Term (°F)
48
Failsafe
(minutes)
60
G
AS
Duration (minutes)
15
O
FFTIME
Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F — open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control — CI/CO
*
FF
–17°F / –29°F
IC
–27°F / –39°F
Indoor Unit Only, Pressure Defrost
Termination
*
Not Recommended
*Use a Temperature Pressure Chart to determine
PSIG conversions.
Estimated Charge (lb)**
8 ft
2.5
12 ft
3.7
**This is an average for all refrigerant types.
Actual refrigerant charge may vary by
approximately half a pound.
Length Added to Lineup by Each
End or Partition (in.)
2
3 of 7
P/N 0465897_D
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
FAN
COIL
15
7
/
8
(404)
47
7
/
8
(1218)
5
1
/
2
(140)
42
1
/
8
(1071)
34
3
/
8
(873)
47
5
/
8
(1209)
49
3
/
8
(1254)
58
(1471)
46
1
/
4
(1175)
35
7
/
8
(910)
3
1
/
8
(79)
24
3
/
8
(618)
FIG
9
7
/
8
(251)
Refrigeration
Outlet
Case-to-Case
Connection
Impact
Excel
FIG
Frozen Food
Intermediate Island Display with Glass Walls
Dimensions shown as inches & (mm).
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF
(National Sanitation Foundation) Standard #7 requirements for