Technical Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

4 of 7

Impact  

Excel

FIG

Frozen Food

Electrical Data

8 ft

12 ft

Number of Fans – 4W Evaporator

2

3

Amperes

Watts

8 ft

12 ft

8 ft

12 ft

Evaporator Fans

120V

60Hz

Standard

0.62

0.93

48

72

120V

50Hz

Standard

0.76

1.14

54

81

230V

60Hz

Export

0.30

0.45

48

72

230V

50Hz

Export

0.36

0.54

54

81

120V

60Hz

Energy Efficient

0.24

0.36

16

24

230V

60Hz

Energy Efficient

0.12

0.18

16

24

Anti-sweat Heaters (on fan circuit)

120V

50/60Hz Standard

0.87

1.30

104

156

230V

50/60Hz Export

0.45

0.68

104

156

Minimum Circuit Ampacity

120V

60Hz

Standard

1.69

2.43

120V

50Hz

Standard

1.83

2.64

230V

60Hz

Export

0.95

1.33

230V

50Hz

Export

1.01

1.42

120V

60Hz

Energy Efficient

1.31

1.86

230V

60Hz

Energy Efficient

0.77

1.06

Maximum Over Current Protection 120V

20

20

Maximum Over Current Protection 230V 

15

15

Return Glass Anti-sweat Heaters

120V

50/60Hz Standard

0.08

0.11

9

13

230V

50/60Hz Export

0.04

0.06

9

13

Discharge Glass Anti-sweat Heaters

120V

50/60Hz Standard

0.46

0.66

55

79

230V

50/60Hz Export

0.24

0.34

55

79

208V Electric Defrost

9.13

13.94

1900

2900

230V Export Electric Defrost

8.26

12.61

1900

2900

120V Koolgas Defrost

1.67

3.33

200

400

Standard Lighting

None

Содержание FIG

Страница 1: ...2 ft case HE 4850623 G Nosing Anti sweat Heaters 8 0495007 8 ft case HE 4850685 0495008 12 ft case HE 4850686 H Return Grille Anti sweat Heaters 9 0495011 8 ft case HE 4850689 0495012 12 ft case HE 48...

Страница 2: ...4 1175 46 1 4 1175 Distance between edges of external legs and center legs 41 1 2 1054 41 1 2 1054 Distance between edges of center legs NA 43 7 8 1114 Distance between front legs and splashguard 3 1...

Страница 3: ...se a Temperature Pressure Chart to determine PSIG conversions Estimated Charge lb 8 ft 2 5 12 ft 3 7 This is an average for all refrigerant types Actual refrigerant charge may vary by approximately ha...

Страница 4: ...104 156 230V 50 60Hz Export 0 45 0 68 104 156 Minimum Circuit Ampacity 120V 60Hz Standard 1 69 2 43 120V 50Hz Standard 1 83 2 64 230V 60Hz Export 0 95 1 33 230V 50Hz Export 1 01 1 42 120V 60Hz Energy...

Страница 5: ...5 30 ft3 ft 0 49 m3 m ARI Total Display Area 3 Sq Ft Ft 3 99 ft2 ft 1 22 m2 m Shelf Area 4 Sq Ft Ft 4 00 ft2 ft 1 22 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit...

Страница 6: ...ation Thermostat Optional 1 BROWN BAND Fans BROWN BAND Nosing Anti sweat Heater 120V POWER 120V NEUTRAL 8 9 Return Grille Anti sweat Heater WARNING All components must have mechanical ground and the m...

Страница 7: ...W HUSSMANN COM Gas Defrost Optional WARNING All components must have mechanical ground and the merchandiser must be grounded Circled Numbers Parts List Item Numbers 7 4 120V Drip Pan Heater Koolgas On...

Отзывы: