Manual RS8EP502 © Danfoss 12-2015
AK-CC 210
Fan stop temperature
The function stops the fans in an error situation, so that they will not provide power
to the appliance. If the defrost sensor registers a higher temperature than the one set
here, the fans will be stopped. There will be re-start at 2 K below the setting.
The function is not active during a defrost or start-up after a defrost.
With s50°C the function is interrupted.
F04
FanStopTemp.
The LED on the controller’s front will indicate whether a defrost is going on.
Fan Relay
Here you can read the fan relay status,
or force-control the relay in “Manual
control” mode.
HACCP
HACCP
HACCP temperature
Here you can see the temperature measurement that transmits signal to the function
h01
HACCP temp.
Last too high HACCP temperature was registered in connection with: (Value can be
read out).
H01: Temperature exceeding during normal regulation.
H02: Temperature exceeding during power failure. Battery backup controls the times.
H03: Temperature exceeding during power failure. No control of times.
h02
-
Last time the HACCP temperature was exceeded: Year
h03
-
Last time the HACCP temperature was exceeded: Month
h04
-
Last time the HACCP temperature was exceeded: Day
h05
-
Last time the HACCP temperature was exceeded: Hour
h06
-
Last time the HACCP temperature was exceeded: Minute
h07
-
Last exceeding: Duration in hours
h08
-
Last exceeding: Duration in minutes
h09
-
Peak temperature
The highest measured temperature will continuously be saved when the temperature
exceeds the limit value in h12. The value can be read out until the next time the tem-
perature exceeds the limit value. After that it is overwritten with the new measure-
ments.
h10
Max.temp.
Selection of function
0: No HACCP function
1: S3 and/or S4 used as sensor. D
efinition takes place in h14.
2: S5 used as sensor.
h11
HACCP sensor
Alarm limit
Here you set the temperature value at which the HACCP function is to enter into
force. When the value becomes higher than the set one, the time delay starts.
h12
HACCP limit
Time delay for the alarm (only during normal regulation).
When the time delay has been passed the alarm is activated.
h13
HACCP delay
Selection of sensors for the measuring
If the S4 sensor and/or the S3 sensor is used, the ratio between them must be set.
At setting 100% only S4 is used. At setting 0% only S3 is used.
h14
HACCP S4%
Internal defrosting schedule/clock function
(Not used if an external defrosting schedule is used via data communication.)
Up to six individual times can be set for the defrost start throughout the day.
Defrost start, hour setting
t01-t06
Defrost start, minute setting (1 and 11 belong together, etc.)
When all t01 to t16 equal 0 the clock will not start defrosts.
t11-t16
Real-time clock
Setting the clock is only necessary when there is no data communication.
In the event of a power failure of less than four hours, the clock function will be saved.
When mounting a battery module the clock function can preserved longer.
There is also a date indication used for registration of temperature measurements.
Clock: Hour setting
t07
Clock: Minute setting
t08
Clock: Date setting
t45
Clock: Month setting
t46
Clock: Year setting
t47
Miscellaneous
Miscellaneous
Delay of output signal after start-up
After start-up or a power failure the controller’s functions can be delayed so that over-
loading of the electricity supply network is avoided.
Here you can set the time delay.
o01
DelayOfOutp.
Содержание CHINO TY3
Страница 6: ...6 Cut and Plan Views ...
Страница 8: ...8 Spec Sheet ...
Страница 9: ...9 01 01 ...
Страница 10: ...10 0 1 0 0 1 1 1 2 0 1 ...
Страница 11: ...11 0 1 0 23 43 5 0 1 0 23 43 5 5 5 1 6 1 1 7 23 43 ...
Страница 12: ...12 0 1 23 23 1 23 23 1 0 1 4 5 0 4 6 0 4 4 4 ...
Страница 42: ...42 Controller for temperature control AK CC 210 User Guide ADAP KOOL Refrigeration control systems ...