9
Tuff Torq K61 Hydrostatic Transaxle
Center Case & Motor Shaft Ass’y Removal
2. After removing the remaining two bolts holding the
Center Case to the Upper Case, place one hand over
the Motor Housing and the other hand over the Cen-
ter Case. While compressing both portions together
slightly, lift the entire assembly from the Upper Case.
(Fig. 22)
Fig. 22, Center Case and Motor Shaft Assemblies
Magnet Removal
1. Loosen (3) Bolts (10 mm) — removing one, on the Cen-
ter Case; remove the Magnet. Clean the Magnet thor-
oughly before reassembling.
(Fig. 21
)
Fig. 21, Magnet Removal
Fig. 20, Center Case and Motor Shaft Assemblies
Hydrostatic Pump Removal
Slide the Brake Drum onto the
Motor Shaft to provide a means of grip-
ing and lifting the Center Case and Mo-
tor Shaft Assemblies from the Upper
Case.
Содержание Tuff Torq K61
Страница 1: ......
Страница 20: ...17 Tuff Torq K61 Hydrostatic Transaxle Hydraulic Flow Diagram ...