DXR 145
DXR 275
DXR 305
DXR 315
Remote control
Battery specification
Nominal 7.2V, 5100 mAh
Battery
2 x Li-ion batteries supplied with the product.
Operation time, h
12
Charge time, h
3
Signal transmission
Radio signal transmission or cable.
Radio frequency bands
2.4 GHz
Max. radio frequency power transmitted, dBm
20
4
Range, m
Up to 300
Dimensions, mm/in.
400x216x291/15.7x8.5x11.5
Weight, kg/lb
3.25/7.2
Protection class
IP65
Operating temperature
-20–60°C /-4–140°F
Storage temperature with battery, °C/°F
Less than 1 month: -20–50°C / 4–122°F
Less than 3 month: -20–40°C / 4–104°F
Less than 1 year: -20–20°C / 4–68°F
Storage temperature without battery, °C/°F
-40–80°C / -40–176°F
Charging temperature, °C/°F
10–45°C /50–113°F
Operating temperatures for the cooling
kit (DXR 275, DXR 305, DXR 315)
At increased ambient temperature it is necessary to cool
down the air at the hydraulic system and the motor. The
maximum temperature for the compressed air is 30°C/
86°F and the maximum pressure is 10 bar/145 PSI.
Ambient temperature less then
40°C / 104ºF
Ambient temperature between
40-50°C / 104-122°F
Ambient temperature between
50-55°C / 122-131°F
Standard
It is not necessary to cool down
the air.
N/A
N/A
Kit 1
It is not necessary to cool down
the air.
N/A
N/A
Kit 2
It is not necessary to cool down
the air.
Pressure,
bar/PSI
6/87
Pressure,
bar/PSI
10/145
Flow, l/min or
cu ft/min
1350/47.7
Flow, l/min or
cu ft/min
1650/58.3
4
13dBm for markets that do not accept 20dBm.
108