OTHER MAINTENANCE 

Guards

Check all guards for damage and proper function daily espe-

cially the blade block. Blade block and cover should be secure 

to the saw and not damaged. Lexan side covers on the blade 

block should move freely up and down.

Diamond blade

Inspect diamond blades daily for damage, cracks, secure fit 

to the arbor, loss of segments, warping or overheating. 

If any 

blade shows any of these problems, discard the blade and 

never use

.

Saw controls

Inspect all controls for proper function daily. 

Check all the in-

terlocks for operation especially the red emergency stop 

button and engine on/off switch for proper operation

.

Belts 

Inspect the blade drive belt and transmission belt for cracks or 

signs of wear. The belt tension is controlled by belt tensioners 

and does not require adjustment. Inspect the belt tensioners 

for free movement up and down. Insure the belt tensioner 

bearings roll freely.

Blade shaft bearings

Lubricate the blade shaft bearings with 3 pumps of Lithium 12 

based grease every 50 hours.

MAINTENANCE SCHEDULE

 

 

 

 

 

 

 

Check guarding, diamond blade,   

 

Daily

skid plate, lexan covers, controls and oil levels.

Clean blade block assembly and saw. 

 

Daily

 

Replace air cleaner. 

 

 

Every 50 hours

 

Replace engine oil.  

 

 

Every 50 hours

Grease blade shaft bearings. 

 

Every 50 hours

 

Check blade drive belt, the transmission 

Every 50 hours

drive belt and belt tensioners.

Replace the fuel filter. 

 

 

             

Annually

Cleaning

Clean the blade block of any excess concrete build up after 

each use. Keep the handle bars and controls clean and dry. 

Immediately clean any spilled fuel from the saw. Keep all 

openings and slot on the saw clean open so air flows freely 

through the engine compartment to insure proper cooling.

WARNING 

Do not modify the saw! Use only Husqvarna Construc-

tion Products replacement parts. Use of unauthorized 

parts may create a danger or damage the engine.

Skid plate

Inspect the skid plate daily for damage, excessive wear in the 

blade slot, burrs on the concrete surface side, twisting and free 

movement up and down when installed on the blade block. 

Replace the skid plate with each new diamond blade. Never 

reuse the skid plates or spalling and raveling may result.

Battery

The battery is maintenance free. If the battery ever requires 

charging, use only a voltage regulated taper current charger 

designed specifically for sealed lead acid gel cell batteries 

rated at 2 amps or less (part # 505583501). A standard auto-

motive, or any other type, battery charger not designed specifi

-

cally for sealed gel batteries will cause permanent damage to 

the installed battery and void any warranty. Do not leave the 

ignition key in the “ON” position as this will drain the battery.

WARNING 

- Connecting and disconnecting a battery can cause 

sparks and short circuits.  Do not short battery ter-

minals by allowing a wrench or any other object to 

contact both terminals at the same time. 

- A spark or flame can cause a lead acid battery to 

explode.

- Before connecting a battery, remove metal  

bracelets, wristwatch bands, rings, etc.  Use gloves 

and protective glasses or face shield when working 

with a battery.

Eye Protection

Explosion Danger

Protective Gloves

Содержание 5000

Страница 1: ...Operator s Manual Read these instructions carefully and make sure you understand them before using the 5000 5000 ...

Страница 2: ...ng the saw Con nect the battery cables and turn the key switch to the ON or 1 position on the instrument panel Press the rocker switch on the instrument panel to raise the saw Place the unloading ramp at the edge of the container and roll the saw out of the container Lower the saw and turn the key switch to the OFF or 0 position CAUTION Only use the center lifting frame when lifting the 5000 The 5...

Страница 3: ...y searching the internet at www husqvarnacp com Husqvarna Construction Products will willingly be of service and provide you with advice as well as help you to use your product both efficiently and safely Additional manuals are available at NO CHARGE and can also be obtained on the internet site Husqvarna Construction Products 265 Radio Road Corona California 92879 USA Toll Free no 800 776 3328 US...

Страница 4: ... in a con fined or badly ventilated area can result in injury or death due to asphyxiation or carbon monoxide poisoning WARNING CALIFORNIA PROP 65 Use of this product can expose you to materials known to the State of California to cause cancer and or birth defects or other reproductive harm WARNING DO NOT MODIFY THE PRODUCT Under no circumstances may the design of the machine be modified without t...

Страница 5: ...ments Do not expose saw to rain Keep work area well lit and clean SAW SAFETY Do not leave saw unattended while the engine is running Do not alter the saw Any alteration or modification is misuse and may result in a dangerous condition All safety guards must be in place before starting the engine Only operate the saw from behind the machine with both hands on the handle Do not use damaged equipment...

Страница 6: ...G Inspect the blade K for any damage Do not use any blade that has cracks nicks flaws or a damaged arbor Make sure the blade is marked with a maximum operat ing speed greater than 2800 rpm Step 4 Match the blade tri arbor to the blade shaft arbor F and install the blade firmly against the rear flange F Insure the blade is installed on the tri arbor correctly Match the female tri arbor of the outer...

Страница 7: ... speed lever H Guide switch I Engine speed switch J Digital display K Engine oil alert light L Light switch M Handle bar height switch N Blade depth switch O Rear access panel P Lifting handle Q Rear guide R Light S Cut depth pointer T Blade block U Hood V Lifting point W Fuel cap gauge X Battery Y Oil dipstick Z Oil fill cap A B C D F H I S T U W X Y Z G J K L M N O P Q R V R ...

Страница 8: ...NG ASPHYXIATION HAZARD Running an engine in a confined or badly ventilated area can result in injury or death due to asphyxiation or carbon monoxide poisoning Open the engine throttle lever to full open position for maxi mum engine speed by pushing the engine speed rocker switch I Lower the front guide to the full down position by depress ing the guide arm rocker switch H Line up the saw with the ...

Страница 9: ...ut to full UP position The self propel function of the saw will not operate with the unit in a raised position Press the engine speed rocker switch I to lower the engine speed Turn the engine kill switch to the OFF or 0 position Lower the saw to the down position NOTE Do not walk on the joints or transport equipment across the joints until the concrete fully hardens DIGITAL DISPLAY J The digital d...

Страница 10: ...illed fuel or oil Replace fuel cap and tighten The Kohler engine is certified to operate on automotive un leaded gasoline with a pump octane rating M R of 87 or higher Fuel tank capacity is 3 0 gallon 11 liter Refuel in a well ventilated area with the engine stopped You may use regular unleaded gasoline containing no more than 10 ethanol E10 Do not use gasoline containing methanol Use of fuels wit...

Страница 11: ...with your local authorities service center or dealer for safe disposal recycling facility ADDITIONAL ENGINE INFORMATION Please see the Kohler Operator s Manual for additional infor mation about servicing the engine The manual also has specific information about specifications tune up parts engine warranty emission compliance etc Air filter The air cleaner assembly G is a canister style that can be...

Страница 12: ...fter each use Keep the handle bars and controls clean and dry Immediately clean any spilled fuel from the saw Keep all openings and slot on the saw clean open so air flows freely through the engine compartment to insure proper cooling WARNING Do not modify the saw Use only Husqvarna Construc tion Products replacement parts Use of unauthorized parts may create a danger or damage the engine Skid pla...

Страница 13: ...t layout should be provided the saw contractor should submit a detailed joint layout for approval prior to cut ting Several factors affect joint spacing including Concrete thickness Type amount and location of reinforcement Shrinkage potential of concrete cement type quantity aggregate size quantity quality water to cement ratio admixtures concrete temperature Base friction Slab restraints Layout ...

Страница 14: ... be cut The timing of the early entry process allows joints to be in place prior to development of significant tensile stress in the concrete The Portland Cement Association PCA engineering bulletin Concrete Floors on the ground also states Proper jointing can eliminate unsightly random cracks Aspects of joining that lead to a good job are choosing the correct type of joint for each location estab...

Страница 15: ...iamond blade to cut at its own rate of speed Check the skid plate for damage or burrs Insure both driver gears are contacting the rear wheel gears all gears and rear wheels are clean and not damaged SAW IS SPALLING AND RAVELLING CUT Check to see if the diamond blade is worn out glazed warped or damaged Insure skid plate moves freely up and down the entire shaft length without contacting the diamon...

Страница 16: ...mim 12 ft min 3 7 m min Blades are available in 14 0 inch 355 mm and 12 inch 305 mm diameters and in 0 100 inch 2 5 mm 0 250 inch 6 4 mm 0 380 inch 9 7 mm and 0 500 inch 12 7 mm widths Engine Kohler Command Pro CH740 Engine oil volume with filter 2 1 quarts 2 0 liters Gasoline tank volume 3 0 gal 11 liters Type Air cooled 4 cycle twin cylinder hydraulic overhead valves gasoline engine Air filter T...

Страница 17: ...applies both during and after the term of this warranty This warranty gives you specific legal rights and other possible rights which may vary from state to state Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you Some states do not allow limitations on how long an implied warranty lasts so the above...

Страница 18: ...2009 14 505 41 78 02 Printed In U S A ...

Отзывы: