background image

ALL PURPOSE INFLATOR OPERATING INSTRUCTIONS

 

 

DO NOT OVER-INFLATE ITEM BEING INFLATED.  FOLLOW MANUFACTURERS 
SUGGESTED PSI LEVELS ON ITEM YOU ARE INFLATING. 

 

WHEN USING HIGH VOLUME INFLATOR TO INFLATE AIR MATTRESSES, RUBBER RAFTS, BEACH 
TOYS, ETC. 

Note:  

Your High Volume Inflator is a great device for inflating or deflating air mattresses, small boats, 

inflatable toys and a host of other items that use a large volume of low pressure air. 

The High Volume Inflator comes with three nozzles of varying sizes to fit most air valves on high volume 
inflatables. 

To Inflate: 

1.  Remove 2 IN 1 All Purpose Inflator from carrying bag and place evenly on flat surface. 
2.  Remove High Volume Inflator from built-in compartment. (Please see image #3 below).     
3.  Remove the 12 Volt power cord from pouch located inside the carrying bag. 
4.  Plug the Power Cord Inlet Plug into the Power Cord Plug-In Outlet. (Please see image #4 below). 
5.  Insert the 12 Volt power cord plug into your vehicle’s 12 Volt DC power outlet. (Please see image #5 

below). 

6.  Select the correct size inflation nozzle, depending on the item you are going to inflate, and attach to the 

port on the High Volume Inflator marked “Inflation Port”.   

Note

: The 3 inflation nozzles fit onto each other/stack on top of each other so as to give the correct air 

tight fit. 

7.  Turn the inflator on by pushing the in-line On/Off power switch to the “I” position.  
8.  Once you have reached the desired air pressure on the item you are inflating, move the On/Off power 

switch to the “O” position.  

9.  Remove the 12 Volt power cord from the DC 12 Volt power outlet. 
10. Remove the nozzle (s) from the High Volume Inflator and store inside built-in compartment. 
11. Return High Volume Inflator to its built-in compartment.   
12. Store the 12 Volt power cord in the pouch inside the carrying bag. 
13. Store your 2 IN 1 All Purpose Inflator in the carrying bag. 

 

To Deflate: 

1. 

If you wish to deflate, follow the same procedure as above using the outlet that is marked “Deflation Port” 
on your High Volume Inflator. 

  

Image

 

#3

 

 

 

   

Image

 

#4

 

 

 

 

Image

 

#5

 

 

 

 

 

 

                                                                     

6

 

Содержание CI12HD1

Страница 1: ...Operator s Manual 2 IN 1 ALL PURPOSE 12 VOLT INFLATOR Model CI12HD1 Safety Guidelines Operation CAUTION Read the Safety Guidelines and All Instructions Carefully Before Operating ...

Страница 2: ...ded in this manual are not intended to cover all possible conditions that may occur during product operation Always use common sense and pay attention to all WARNING and CAUTION statements in this manual Work Area Keep your work area clean and well lit Cluttered benches and dark areas increase the possibility of personal injury or property damage Do not operate power tools in explosive atmospheres...

Страница 3: ...int your inflator fails to operate check the fuse in the end of the 12 Volt plug To replace the fuse simply unscrew the 12 Volt power plug tip remove existing fuse install new fuse and reassemble power plug tip Use only an AGC 13 Amp replacement fuse Working current at 32 PSI 7 6A Max amperage 13A 40 SCFM 30 PSI Max Pressure 130 PSI TROUBLESHOOTING 2 PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION Unit w...

Страница 4: ...wer cord as damage may occur Do not leave the inflator unattended while in operation Do not over inflate item you are inflating Please follow the manufacturer s instructions for the item you are inflating Keep the inflator away from flammable areas liquids at all times Do not operate the inflator in wet or damp areas Operate the inflator only with the accessories and or attachments that are includ...

Страница 5: ...Handle E 12 Volt Power Cord F In Line On Off Power Switch G Power Cord Inlet Plug H 12 Volt Power Cord Plug I Presta Valve Adaptor J Sports Needle K Power Cord Plug In Outlet L Quick Connect Valve Adaptor M Deflation Port N High Volume Inflator O Inflation Nozzles P Power Cord Plug In Outlet Q Inflation Port R Air Hose Storage S Air Hose T Carrying Bag 4 ...

Страница 6: ...il it is securely attached to the tire air valve See NOTE below 6 Turn the inflator on by pushing the in line On Off power switch to the I position Monitor the PSI on the pressure gauge to fill your item to desired air pressure 7 Once you have reached the desired air pressure move the On Off power switch to the O position 8 Remove the air hose from the tire by lifting up on the valve lever You wil...

Страница 7: ...he 12 Volt power cord plug into your vehicle s 12 Volt DC power outlet Please see image 5 below 6 Select the correct size inflation nozzle depending on the item you are going to inflate and attach to the port on the High Volume Inflator marked Inflation Port Note The 3 inflation nozzles fit onto each other stack on top of each other so as to give the correct air tight fit 7 Turn the inflator on by...

Страница 8: ...al del Usuario INFLADOR 2 EN 1 MULTIUSO DE 12 VOLTIOS Modelo CI12HD1 Normas de Seguridad Operación PRECAUCIÓN Lee las Normas de Seguridad y Todas las Instrucciones Cuidadosamente antes de Operar el Inflador ...

Страница 9: ...de seguridad en este manual no pretenden cubrir todas las condiciones posibles que pueden producirse durante la operación del producto Siempre usa el sentido común y presta atención a todas las ADVERTENCIAS y PRECAUCIONES de este manual Área de Trabajo Mantener el área de trabajo limpia y bien iluminada Un banco de trabajo desordenado o un área de trabajo oscura aumentan la posibilidad de lesiones...

Страница 10: ...ible en el extremo del enchufe de 12 Voltios Para reemplazar el fusible simplemente desatornilla la punta del enchufe de 12 Voltios quita el fusible existente instala el nuevo fusible y vuelve a colocar la punta del enchufe Usa sólo un fusible de repuesto AGC de 13 A Corriente de funcionamiento a 32 PSI 7 6A Amperaje máx 13A 0 40 SCFM a 30 PSI Presión Máx 130 PSI SOLUCIÓN DE PROBLEMAS 2 PROBLEMA P...

Страница 11: ...los niños en todo momento No traslades el inflador por la manguera de aire o por el cable de alimentación ya que puede producir daños No dejes el inflador desatendido mientras está funcionando No infles en exceso Por favor sigue las instrucciones del fabricante para el artículo que estés inflando Mantén el inflador lejos de las zonas líquidos inflamables en todo momento No utilices el inflador en ...

Страница 12: ...On Off en Línea G Enchufe de Cable de Entrada H Enchufe de Cable de 12 Voltios I Adaptador de Válvula Presta J Aguja para Artículos Deportivos K Tomacorrientes para el Cable de Alimentación L Adaptador de Válvula de Conexión Rápida M Terminal de Desinflado N Inflador de Alto Volumen O Boquillas de Inflación P Tomacorrientes para el Cable de Alimentación Q Terminal de Inflado R Almacenamiento de Ma...

Страница 13: ...ujeta firmemente a la válvula de aire del neumático Ver NOTA a continuación 6 Enciende el inflador moviendo el interruptor de Encendido Apagado On Off a la posición I Controla el PSI en el manómetro para inflar tu artículo hasta la presión deseada 7 Una vez alcanzada la presión de aire deseada apaga el inflador moviendo el interruptor a la posición O 8 Retira la manguera de aire del neumático leva...

Страница 14: ...a el enchufe del cable de 12 Voltios en los tomacorrientes de 12 Voltios CC de tu vehículo Ver imagen No 5 a continuación 6 Selecciona la boquilla de inflado del tamaño correcto dependiendo del objeto que vayas a inflar y colócala en el terminal del Inflador de Alto Volumen que dice Inflation Port Terminal de Inflado Nota Las 3 boquillas de inflado se acoplan apilan una arriba de la otra para perm...

Страница 15: ...HOME DEPOT U S A INC 2455 PACES FERRY RD N W ATLANTA GA 30339 WWW HUSKYTOOLS COM ...

Отзывы: