SPECIFICATIONS
THIS INFLATOR OPERATES ONLY ON DC 12 VOLT. DO NOT ATTEMPT TO OPERATE
THIS INFLATOR WITH ANY OTHER SOURCE OR VOLTAGE. DO NOT REWIRE OR RECONFIGURE
INFLATOR FROM ITS ORIGINAL DESIGN OR PERSONAL INJURY OR BODILY HARM MAY OCCUR.
Voltage
DC 12 Volt
Power Requirement
DC 12 Volt – For use with 12 Volt DC Power Outlet Only
Note:
This unit is equipped with fuse protection
. If at some point your inflator fails to operate, check
the fuse in the end of the 12 Volt plug. To replace the fuse, simply unscrew the 12 Volt power plug tip,
remove existing fuse, install new fuse and reassemble power plug tip. Use only an AGC – 13 Amp
replacement fuse.
Working current at 32 PSI: 7.6A
Max amperage: 13A
.40 SCFM @ 30 PSI
Max Pressure : 130 PSI
TROUBLESHOOTING
2
PROBLEM POSSIBLE
CAUSE
CORRECTIVE
ACTION
Unit will not start.
1. Cord not plugged in.
2. Fuse in 12 Volt DC
power cord blown.
1. Plug into a working 12 Volt DC Power Outlet.
2. Replace 13 Amp fuse in 12 Volt DC power
cord. (Please see image below).