16
Figure 9. Gas Charger Valve
d. Open the main gas valve on the N
2
gas container and regulate the N
2
gas pressure
(see Figure 8.)
e. Turn the gas charger “T” handle clockwise and adjust N
2
gas pressure in the gas
chamber to the correct gas pressure shown on Table 10, Page 26.
f. Turn the gas charger “T” handle fully counter clockwise and remove the hose.
Attach the cap to the gas inlet of the charger.
g. Remove the gas charger and attach the gas valve cap and O ring firmly to the gas
valve nut on the hammer back cap.
OIL LEAKAGE INSPECTION
Check for oil leakage at the points shown in Table 5. It is not unusual to have a small
amount of oil leakage along the tool or cylinder, (refer to Figure 10.)
Table 5. Diagnosis of Oil Leakage
LEAK LOCATION
POSSIBLE CAUSE
REMEDY
Between front cap
and tool (E)
Damaged or worn
U-packing
Replace seal kit
Between cylinder and
nipple (F)
Loose nipple or damaged
O-ring or nipple
Tighten or replace nipple,
and / or O-ring
Between cylinder and
back cap (G)
Damaged U-packing or
main
Valve outer sleeve O-ring,
or
Back cap O-ring
Replace seal kit
Plug ports (H)
Plugs loosen
Remove plugs and reinstall
with sealant
Содержание HH1500
Страница 1: ...1 HUSKIE HYDRAULIC HAMMERS SERVICE MANUAL HH1500 HH2000 HH3600 HH4500 HH5800 HH8000...
Страница 33: ...33 9 PARTS LIST AND ILLUSTRATIONS HH1500 HH2000 HH3600 HH4500 HH5800 HH8000...
Страница 35: ...35 Effective 07 05 HH1500 HAMMER...
Страница 37: ...37...
Страница 39: ...39 HH2000 HAMMER UP TO S N 2K031 SOLD BEFORE 9 96 Effective 07 05...
Страница 41: ...41 Effective 07 05 HH2000 HAMMER S N 3K001 UP SOLD AFTER 10 96...
Страница 43: ...43...
Страница 45: ...45 HH 3600 2 HAMMER S N 5M1000 UP Effective 07 05...
Страница 47: ...47...
Страница 49: ...49 HH4500 HAMMER Effective 07 05...
Страница 51: ...51...
Страница 53: ...53 HH5800 HAMMER Effective 07 05...
Страница 55: ...55...
Страница 57: ...57 HH8000 HAMMER Effective 07 05...
Страница 59: ...59 NOTES...