Hupfer 0129470 Скачать руководство пользователя страница 12

Chapter3

 

Description and Technical Data 

Page12 

Performance Description

 

Mobile bain marie  

 

SPA/K-2DW | SPA/K-3DW 

4330036_A1

 

Description and Technical Data 

3.1 

Performance Description 

Mobile bain maries are mobile appliances with continuous seamless cooling wells and active static cooling. 
Their purpose is to keep cold products which are introduced cold in closed compartments. 

The principal field of use is the distribution of food from Gastronorm containers or of individually packaged 
cold food. 
Another typical field of use of mobile bain maries is as mobile cold drink serving unit for event catering. 
Mobile bain maries can be used in Cook&Chill kitchens to accommodate and cool food in Gastronorm con-
tainers, which should be regenerated at a later time. 

The storage period of cold food is not limited by the equipment. With cooling switched on, the appliance can 
be stocked as early as the previous day. The cooling ensures that transport, storage and serving can take 
place in accordance with the LMHV and HACCP guidelines. When cooling meals or their components, it is 
necessary to comply with the respective legal directives on food storage (duration and temperature). 

3.2 

Proper Use 

Mobile bain maries are intended to accommodate and transport cold food in Gastronorm containers or indi-
vidually packaged drinks and desserts. Use of other loads is not permitted. 

When stored meals are kept properly, it is necessary to check and verify the compliance of the prescribed 
storage temperatures with appropriate measuring instruments (thermometers) before the distribution of 
meals. 

Any other use of the appliance is considered as unintended use. 

Proper use includes observing defined procedures, compliance with the stated specifications and use of 
supplied or additionally available original accessories. 

3.3 

Improper Use 

Mobile bain maries are intended for keeping products cold which have been introduced in the cold state. 
Warm meals should not be put into the appliance. 

The permitted ambient temperature may not be exceeded. 

The appliances should not be exposed to direct sunlight. 

In no case may people sit down or stand on or in to the appliance. 

Any other use, especially loading the mobile bain marie with other loads as specified, is not permitted. 

The manufacturer and suppliers are not liable for any consequential damage resulting from unintended use. 
No liability is assumed and no warranty claims can be submitted for damages caused by improper use. 

Содержание 0129470

Страница 1: ...4330036_A1 Operating Instructions Mobile bain marie SPA K 2DW SPA K 3DW...

Страница 2: ...ting instructions to ensure safe operation and avoid any damage Ensure that sources of danger and possible incorrect handling have been pointed out to the operating staff Subject to modifications The...

Страница 3: ...s for Cleaning and Care 11 2 6 Safety Instructions for Troubleshooting 11 2 7 Notes on Specific Hazards 11 3 Description and Technical Data 12 3 1 Performance Description 12 3 2 Proper Use 12 3 3 Impr...

Страница 4: ...marie SPA K 2DW SPA K 3DW 4330036_A1 7 Cleaning and Care 23 7 1 Safety Measures 23 7 2 Hygiene Measures 23 7 3 Cleaning and Care 23 7 4 Special Care Instructions 24 8 Spare Parts and Accessories 26 8...

Страница 5: ...f water 1 Protection against contact with any large surface of the body such as the hand protection against ingress of foreign objects 1 97 50 mm 1 Protection against dripping water verti cally fallin...

Страница 6: ...conditions and or characteristics such as damage leaks filling levels heat LMHV Regulation on the Hygiene of Foodstuffs Regulation on the requirements concerning hygiene when producing handling and pl...

Страница 7: ...are arranged The operating staff stays at this side to move the mobile bain marie The rear The rear denotes the opposite side of the front side the front The right Right refers to the right hand side...

Страница 8: ...ted by a symbol and explained in the accompany ing text in more detail The general symbol for danger is used in this example WARNING Brief description of danger There is an indirect danger to life and...

Страница 9: ...symbols can be used General hazardous area Hazardous electrical voltage 2 3 Safety Instructions for Appliance Safety Safe operation of the appliance depends on correct and careful use Negligent handli...

Страница 10: ...cks insignificantly out of the socket and so cannot be damaged by being hit at the side If the appliance is moved without pulling out the mains plug beforehand the socket can be severely damaged or ev...

Страница 11: ...ut of operation switch it off pull out the mains plug and secure it against unauthorised reactivation before performing maintenance or troubleshooting operations When work ing on the electrical instal...

Страница 12: ...ves on food storage duration and temperature 3 2 Proper Use Mobile bain maries are intended to accommodate and transport cold food in Gastronorm containers or indi vidually packaged drinks and dessert...

Страница 13: ...rocess without the formation of ice or bloom on the condenser or the ne cessity to intervene manually in the automatic defrosting cycles The maximum cooling capacity will automat ically be called up T...

Страница 14: ...de of stainless steel 4 92 125 mm with and without total brakes pin fixing The part numbers of the special accessories can be found in the spare parts catalogue and order lists avail able online 3 5 T...

Страница 15: ...ding certification marks are available from our homepage at www hupfer de 3 6 Rating Plate Figure 2 Rating plate 1 Disposal of old appliances 9 Nominal current 2 Certification mark 10 Frequency 3 Prot...

Страница 16: ...ation The mobile bain marie is delivered as an assembled unit i e it is completely assembled including the cooling element When loading use only hoists and load lifting devices approved for the weight...

Страница 17: ...e kept covered with a suitable covering material to be protected against dust ingress The appliance kept in the storage location must be checked for damage and corrosion every 6 months NOTE Condensed...

Страница 18: ...ide of the cooling element below the cooling well Figure 3 Operating elements SPA K 2DW 5 2 Operation ATTENTION Contamination by germs Microorganisms from the air may get into the GN containers and co...

Страница 19: ...ners GN 2 1 and GN 1 1 containers can be put into the cooling well without further action When using smaller Gastronorm containers support bars must be used in order to ensure sealing with the well ri...

Страница 20: ...Only open the water drain taps directly above an on site drain duct or a drain at the bottom Use a drain container with a sufficient volume or a drain extension tube Figure 4 Opening the water drain t...

Страница 21: ...disruptions to operation and ensure safety In spection and maintenance intervals depend on the use of the appliance Consult your dealer s after sales service department 6 3 Fault and Action Table Fau...

Страница 22: ...he walls of the cooling well reduced cooling power Introduction of too warm uncovered or too moist food Disconnect the appliance from the power supply and clean the walls of the well with warm water C...

Страница 23: ...ugh on clean crockery or meals 7 3 Cleaning and Care If the mobile bain marie is handled with care cleaned and maintained on a regular basis it does not require any additional care measures The coolin...

Страница 24: ...ces are for example substances containing salt and sulphur chlorides salts seasoning concentrates e g mustard vinegar essence seasoning cubes saline solutions Further damages can occur due to extraneo...

Страница 25: ...ct with iron and steel should be avoided because that leads to ex traneous rust If stainless steel comes into contact with iron steel wool steel particles from pipes wa ter containing iron this can be...

Страница 26: ...2DW 014034048 OBO Quick clamp PG16 type 2142740 set Package contents 5 piece 014034026 Brass ball valve 1 2 set Package contents 2 piece 91198397 Reducer Brass chromium plated 3 4 1 2 4001648 Cooling...

Отзывы: