Mobile bain marie 

4330036_A1

 

SPA/K-2DW | SPA/K-3DW

 

2.5 

Safety Instructions for Cleaning and Care 

The following points must be observed when carrying out any cleaning and maintenance operations: 

§

 

The cleaning instructions must be strictly observed for reasons of hygiene. 

§

 

Take the appliance out of operation before starting the cleaning process. Pull out the mains plug and 
insert it into the holder located on the appliance. 

§

 

Never flood the appliance with water for cleaning purposes. There is danger to life, when the appli-
ance is reconnected to the mains. 

§

 

Do not clean the appliance with steam-jet or high-pressure washers. The appliance must be taken out 
of operation and switched off at the mains beforehand in any area where steam-jet or high-pressure 
washers are to be used. 

§

 

Do not tilt the appliance for cleaning. If this cannot be avoided, keep it in a vertical position for two 
hours before putting it into operation, so that the coolant can flow back into its initial position. 

2.6 

Safety Instructions for Troubleshooting 

The following points shall be observed when carrying out any maintenance and troubleshooting operations: 

§

 

The local applicable Accident Prevention Regulations must be observed. 

§

 

Take the mobile bain marie out of operation, switch it off, pull out the mains plug and secure it against 
unauthorised reactivation before performing maintenance or troubleshooting operations. When work-
ing on the electrical installation, the appliance must be switched off at the mains and secured against 
reactivation. This work must only be carried out by an electrician. 

§

 

Observe the valid product safety regulations for the product when handling oils, greases and other 
chemical substances. 

§

 

Carry out all the checks and inspections of the appliance on a regular basis. Remedy immediately de-
ficiencies, such as loose screw connections or damaged connecting leads. 

§

 

Only authorised specialists may perform all repair work. 

§

 

Only use original spare parts to replace defective components. 

§

 

Do not tilt the appliance for troubleshooting. If this cannot be avoided, keep it in a vertical position for 
two hours before putting it into operation, so that the coolant can flow back into its initial position. 

2.7 

Notes on Specific Hazards 

Electrical energy 

§

 

All work on the electrical installations should only be carried out by an electrician or by authorised 
specialists under supervision and monitoring of a certified electrician according to the applicable elec-
tro-technical regulations. 

§

 

The appliances on which inspection, maintenance and troubleshooting work is performed must be 
disconnected from the power supply and secured against reactivation when voltage is not required for 
this kind of work. This must only be carried out by an electrician. 

Содержание 0129470

Страница 1: ...4330036_A1 Operating Instructions Mobile bain marie SPA K 2DW SPA K 3DW...

Страница 2: ...ting instructions to ensure safe operation and avoid any damage Ensure that sources of danger and possible incorrect handling have been pointed out to the operating staff Subject to modifications The...

Страница 3: ...s for Cleaning and Care 11 2 6 Safety Instructions for Troubleshooting 11 2 7 Notes on Specific Hazards 11 3 Description and Technical Data 12 3 1 Performance Description 12 3 2 Proper Use 12 3 3 Impr...

Страница 4: ...marie SPA K 2DW SPA K 3DW 4330036_A1 7 Cleaning and Care 23 7 1 Safety Measures 23 7 2 Hygiene Measures 23 7 3 Cleaning and Care 23 7 4 Special Care Instructions 24 8 Spare Parts and Accessories 26 8...

Страница 5: ...f water 1 Protection against contact with any large surface of the body such as the hand protection against ingress of foreign objects 1 97 50 mm 1 Protection against dripping water verti cally fallin...

Страница 6: ...conditions and or characteristics such as damage leaks filling levels heat LMHV Regulation on the Hygiene of Foodstuffs Regulation on the requirements concerning hygiene when producing handling and pl...

Страница 7: ...are arranged The operating staff stays at this side to move the mobile bain marie The rear The rear denotes the opposite side of the front side the front The right Right refers to the right hand side...

Страница 8: ...ted by a symbol and explained in the accompany ing text in more detail The general symbol for danger is used in this example WARNING Brief description of danger There is an indirect danger to life and...

Страница 9: ...symbols can be used General hazardous area Hazardous electrical voltage 2 3 Safety Instructions for Appliance Safety Safe operation of the appliance depends on correct and careful use Negligent handli...

Страница 10: ...cks insignificantly out of the socket and so cannot be damaged by being hit at the side If the appliance is moved without pulling out the mains plug beforehand the socket can be severely damaged or ev...

Страница 11: ...ut of operation switch it off pull out the mains plug and secure it against unauthorised reactivation before performing maintenance or troubleshooting operations When work ing on the electrical instal...

Страница 12: ...ves on food storage duration and temperature 3 2 Proper Use Mobile bain maries are intended to accommodate and transport cold food in Gastronorm containers or indi vidually packaged drinks and dessert...

Страница 13: ...rocess without the formation of ice or bloom on the condenser or the ne cessity to intervene manually in the automatic defrosting cycles The maximum cooling capacity will automat ically be called up T...

Страница 14: ...de of stainless steel 4 92 125 mm with and without total brakes pin fixing The part numbers of the special accessories can be found in the spare parts catalogue and order lists avail able online 3 5 T...

Страница 15: ...ding certification marks are available from our homepage at www hupfer de 3 6 Rating Plate Figure 2 Rating plate 1 Disposal of old appliances 9 Nominal current 2 Certification mark 10 Frequency 3 Prot...

Страница 16: ...ation The mobile bain marie is delivered as an assembled unit i e it is completely assembled including the cooling element When loading use only hoists and load lifting devices approved for the weight...

Страница 17: ...e kept covered with a suitable covering material to be protected against dust ingress The appliance kept in the storage location must be checked for damage and corrosion every 6 months NOTE Condensed...

Страница 18: ...ide of the cooling element below the cooling well Figure 3 Operating elements SPA K 2DW 5 2 Operation ATTENTION Contamination by germs Microorganisms from the air may get into the GN containers and co...

Страница 19: ...ners GN 2 1 and GN 1 1 containers can be put into the cooling well without further action When using smaller Gastronorm containers support bars must be used in order to ensure sealing with the well ri...

Страница 20: ...Only open the water drain taps directly above an on site drain duct or a drain at the bottom Use a drain container with a sufficient volume or a drain extension tube Figure 4 Opening the water drain t...

Страница 21: ...disruptions to operation and ensure safety In spection and maintenance intervals depend on the use of the appliance Consult your dealer s after sales service department 6 3 Fault and Action Table Fau...

Страница 22: ...he walls of the cooling well reduced cooling power Introduction of too warm uncovered or too moist food Disconnect the appliance from the power supply and clean the walls of the well with warm water C...

Страница 23: ...ugh on clean crockery or meals 7 3 Cleaning and Care If the mobile bain marie is handled with care cleaned and maintained on a regular basis it does not require any additional care measures The coolin...

Страница 24: ...ces are for example substances containing salt and sulphur chlorides salts seasoning concentrates e g mustard vinegar essence seasoning cubes saline solutions Further damages can occur due to extraneo...

Страница 25: ...ct with iron and steel should be avoided because that leads to ex traneous rust If stainless steel comes into contact with iron steel wool steel particles from pipes wa ter containing iron this can be...

Страница 26: ...2DW 014034048 OBO Quick clamp PG16 type 2142740 set Package contents 5 piece 014034026 Brass ball valve 1 2 set Package contents 2 piece 91198397 Reducer Brass chromium plated 3 4 1 2 4001648 Cooling...

Отзывы: