Fig. 1

���������������

��������������

������������������

����

�����

���

����

�����

���

�� �� � ��

SRR Remote Control

 Smart Port

®

 Wiring Harness

Preparing the Communication Port

To utilize the SRR Remote Control 

System, your Hunter controller must be 

equipped with the SRR SmartPort

®

 wiring 

harness. This wiring harness provides 

the communication port where the SRR 

receiver is attached. The SmartPort

®

 

installation instructions are included in the 

SRC 

Plus

 installation and programming 

instructions. Additional wiring harnesses 

can be purchased separately to allow you 

to utilize the transmitter and receiver with 

additional controllers.

Installing the SRR Remote 

Wiring Harness

1.  Install a 1⁄2" female threaded “Tee” in 

the field wiring conduit approximately 

12" below the SRC controller. (Note: 

the harness may be installed out doors 

by first bringing the conduit through 

an exterior wall, then installing the 

appropriate fitting).

2.  Feed the red, white and blue wires of 

the harness through the base of the 

“Tee” and into the controller wiring 

compartment as shown in Figure 1.

3.  Screw the harness housing into the 

“Tee” (or other fitting) as shown in 

Figure 1.

4.  Attach the red, white and blue wires 

from the harness to the terminal block 

of the controller as shown in Figure 2.

�� ��

��

��

��� ����� ����

Fig. 2

Extending the Wiring Harness

Any extension of the wiring on the 

harness 

may

 result in an error message 

in the controller display and possible 

malfunction of the remote unit due to 

radio interference. In some situations, 

lengthening of the harness may work 

fine, in others it may not work at all (it 

is site specific). In either case, extending 

the wiring harness should be done using 

shielded cable to minimize the possible 

effects of electrical noise. Hunter

s SCWH 

is a wiring harness with 25 feet of shielded 

cable which makes extending the receiver 

connection fast and simple.

Transmitter

Preparing the Transmitter for Use

Your SRR System is designed to work 

right out of the box. This means that 

other than installing the battery, you 

may chose to skip this entire section. 

However, we recommend you read it 

because with a few simple steps you can 

customize your SRR to add functionality 

and security to your system. Be aware that 

if you change your transmitter address or 

maximum station number as described 

Assembled

INSTALLATION AND PROGRAMMING 

Pre-assembled

1⁄2

" Thread

To Controller

Содержание SRC Plus

Страница 1: ... R O D U C T I N F O R M AT I O N G U I D E S R C P L US CONTR O L L E R Plus Plus SRC Plus Controllers Professional Grade Residential Light Commercial Controller with Optional SRR Remote Control System ...

Страница 2: ...n 9 Product Comparisons 10 Installation 11 Programming 15 Troubleshooting Guide 20 Optional SRR Remote Control for Residential Systems Product Overview 21 Product Features and Benefits 22 SRR Components 24 Installation and Programming 25 A Word About Range 29 Troubleshooting Guide 30 Technical Information 31 Installation Details 32 ...

Страница 3: ...nnections to the terminal block The controllerʼs easy to understand dial allows you to step through the programming process and activate manual watering with a twist of the wrist youʼll also find the large LCD display makes viewing a breeze And as for features how about a choice between a 6 or 9 station model Remote Control Ready three full programs with up to four daily start times each a one tou...

Страница 4: ...tion rate soils slopes morning or evening irrigation and other watering win dow restrictions 365 day Calendar with Leap Year Intelligence True odd or even day programming In many areas of the United States summer water rationing is a way of life With its 365 day leap year intelligent calendar the SRC makes programming true Odd Even day watering possible automatically correcting for 31 day months I...

Страница 5: ...ime The controller will begin to operate that station within 2 seconds If no buttons are pressed during step 2 or 3 the controller will automatically begin program A After the selected station has completed its altered run time the controller will then proceed to water subsequent stations with their original programming in sequential order only It will not water previous stations Large LCD display...

Страница 6: ...s preventing system operation just turn the dial to Run Bypass Sensor and the rain sensor will be overridden RUN NEXT PROGRAM START TIMES STATION RUNTIME YEAR MONTH DAY RUNNING AM PM 24 HR SUN MON TUES WED THUR FRI SAT EVEN ODD SYSTEM OFF RUN BYPASS SENSOR SET DAYS TO WATER MANUAL SINGLE STATION MANUAL ALL STATIONS SET CURRENT DATE TIME SET WATERING START TIMES SET STATION RUN TIMES Plus Plus PROG...

Страница 7: ...sition After the controller completes the manual watering it will return to the original schedule even if modified for the manual operation Time Saving Mounting Bracket Quicker neater easier installation No need for special mounting templates and directions With the SRC just hang the wall bracket and slide the controller onto the bracket With the special wall bracket there is extra stabilization o...

Страница 8: ...red in the controller and is not affected by the System Off setting Interchangeable Faceplate Label Allows for language customization The faceplate instructions can be changed to either Spanish French or Italian by the user in the field Complete language customization kits include a faceplate label a door instruction label and an owner s manual Program Overlap Protection Assures proper system oper...

Страница 9: ...icate what zone is shorting by showing the station number followed by ERR in the LCD display The controller will continue to jump over that zone during every watering until the zone is repaired To remove the ERR message from the display just turn the dial or push any button Upgrade to Centralized Control Network through IMMS to make programming changes and monitor system conditions from your compu...

Страница 10: ...ton Increases the selected flashing display Button Decreases the selected flashing display Button Advances the selected flashing display Button Selects program A B or C C Transformer A 120 VAC Plug in transformer included in SRC 600i and 900i models supplies 24 VAC to the controller D Control Dial Run Normal dial position for automatic and manual operation Run Bypass Sensor Used to disengage optio...

Страница 11: ...t 120 VAC 60 Hz 220 VAC 50 60 Hz international use transformer not included with export units Transformer output 24 VAC 0 75A Station output 24 VAC 0 3A per station Maximum total output 24 VAC 0 6A includes master valve circuit Battery backup 9 volt alkaline battery in separate com partment not required for program backup Non volatile memory for program data Electronic short circuit protection Hun...

Страница 12: ...it Pump Start Relay Optional Large Wiring Compartment for Easy Access to Wiring Professional Protective Door on Cabinet Provision for Conduit Clean Installation kit add on Time Saving Mounting Bracket Easy to View Reference Label in Controller Door Foreign Language Faceplate Labeling Optional Foreign Language Owner s Manuals Optional Electronic Short Circuit Protection Non volatile Memory Maintain...

Страница 13: ...orresponding to each valve and the watering station it controls 3 Secure the wires with a waterproof wire connector to protect the connection 4 Open hinged wiring compartment door to access the terminal strip area shown in the diagram 5 Route the valve wires through the large opening on the base of the cabinet or through 1 2 inch conduit if installed Strip 1 4 inch of insulation from ends of all w...

Страница 14: ...not be able to activate any of the station valves Electrical power must resume before watering will continue Connecting a Master Valve NOTE Complete this section only if you have a master valve installed A master valve is a normally closed valve installed at the supply point of the main line that opens only when the automatic system is activated 1 At the Master Valve attach the common wire to eith...

Страница 15: ...a separate electrical circuit to energize a pump to provide water to your system The controller should be mounted at least 15 feet 4 5m away from both the pump start relay and the pump When a pump start relay comes on it sends out surges that may potentially cause damage to a controller that is mounted to close When a pump is to be operated by the controller a pump start relay must be used Hunter ...

Страница 16: ...e SRC Plus The purpose of this sensor is to stop watering when precipitation is sufficient The sensor connects directly to the controller and allows you to easily override the sensor by using the RUN BYPASS SENSOR position on the dial 1 Route the wires from the rain sensor up through the same opening used for valve wiring 2 Connect one wire to the RS terminal and the other to the C terminal 3 Conn...

Страница 17: ...ate the days of the week you want to water The SRC makes it easy NOTE A basic programming rule is that whatever symbol or character is flashing will be the item programmed For instance if the hour is flashing when setting the time the hour can be changed or programmed For illustration purposes flashing characters are in GRAY type Setting the Date and Time 1 Turn the dial to the SET CURRENT DATE TI...

Страница 18: ...FF position NOTE If a program has all four start times turned off then that program is off All other program details are retained Because there are no start times there will be no watering with that program This is a convenient way to stop watering on one program only without turning the dial to the OFF position Setting Station Run Times Length of Watering for Each Area 1 Turn the dial to the SET ...

Страница 19: ... of specific days of the week Odd days 1st 3rd 5th etc Even days 2nd 4th 6th etc 1 Press the button until the arrow cursor is above either EVEN or ODD on the display 2 Press the button to select or the button to cancel either Odd Days or Even Days The previous selected days of the week will revert to active if Odd Days or Even Days is cancelled NOTE The 31st of any month and February 29 are always...

Страница 20: ...r then controller will return to automatic mode with no change in the previously set program NOTE The station that is on the display when you turn the dial to RUN will be the first station to run The controller will then proceed to water in sequential order only It will not water previous stations Example If you turn the dial to RUN with the display reading station 3 The controller will water stat...

Страница 21: ...circuit test procedure This circuit diagnostic procedure is very beneficial because of its ability to aid in quickly identifying shorts commonly caused by faulty solenoids or when a bare common wire touches a bare station control wire To initiate the Hunter Quick Check test procedure Press the and and buttons simultaneously In the standby mode the LCD will display all segments helpful when trouble...

Страница 22: ...ster valve or pump start wire for continuity Replace or repair the broken wire Check that all wire connections are good and water tight The display reads a station number and ERR such as 2 ERR There has been a ground fault with the wire leading to that station Check the station wire for continuity Replace or repair broken wire Check that all wire connections are good and water tight The display re...

Страница 23: ...et in the way It features a large LCD and four button operation Donʼt let its size fool you while it s small enough to fit in your shirt pocket it has an open field range of up to 450 feet The large LCD display and simple four button control make the SRR a snap to use Simply press the or keys to display the station or program you want to turn on or off then press the or button what could be easier...

Страница 24: ...elf off to extend battery life It can be reactivated by touching any button Small and Compact Size Slips into shirt or pants pocket Both the transmitter and receiver are small enough to fit into the palm of your hand And because they are so compact they can be easily transported in a shirt or pants pocket during daily uses Standard 9V Alkaline Battery Easy to purchase and lasts a long time Any con...

Страница 25: ...mitter address may be changed to any setting from 0 127 for added security The receiver will then learn the address The programmable address is useful for areas where multiple homes or buildings are utilizing SRR remotes Programmable Number of Stations Controlled Customize the remote to the number of stations on the controller The SRR is fully reprogrammable and can access up to 48 stations allowi...

Страница 26: ... Control Buttons 5 Increases the selected flashing display 6 Decreases the selected flashing display 7 Selects the selected flashing display 8 Cancels the selected flashing display C Other 9 Battery Cover Covers compartment for 9 volt alkaline battery RECEIVER 10 Control Button Hold button down when plugging Receiver into SmartPort when programming a new address 11 SmartPort Outlet Male Outlet on ...

Страница 27: ...ting as shown in Figure 1 4 Attach the red white and blue wires from the harness to the terminal block of the controller as shown in Figure 2 Fig 2 Extending the Wiring Harness Any extension of the wiring on the harness may result in an error message in the controller display and possible malfunction of the remote unit due to radio interference In some situations lengthening of the harness may wor...

Страница 28: ...you should make a note of the new settings since when the battery is removed and a new one installed the transmitter will revert back to the original settings Installing the Transmitter Battery Your SRR Transmitter requires a 9 volt alkaline battery To install the battery slide open the battery door on the back of the transmitter attach the battery to the clip insert the battery and slide the door...

Страница 29: ...mitter will first illuminate the entire display for 1 second then display the active station 2 Simultaneously press the and buttons until the word RUN TIME along with the current Run Time is displayed default is 10 minutes The display will be blinking at this point If more than 5 seconds go by without a button being pressed the Transmitter will revert back to displaying the active station 3 Use th...

Страница 30: ...the Maximum Station Number Your SRR Transmitter comes from the factory with the maximum station number set to 9 This means that when you use the and buttons to change the station you may change it to any number between 1 and 9 However if you only have a 6 station controller you will never need to access stations 7 9 Likewise perhaps you will own a future Hunter controller with more than 9 stations...

Страница 31: ...systems whether they be for auto alarms garage doors or irrigation systems for that matter The published range for the SRR System is up to 450 feet Most users will achieve this range or more but a few may not It is the attempt of this section to educate the user about those factors that influence operating range We believe that we have achieved the maximum performance available on this frequency H...

Страница 32: ...t match Relearn address at receiver Transmitter display stays on Transmitter will turn off automatically Wait approximately 5 minutes without pressing any buttons Transmitter will fall asleep ERR message in controller display when controller is in the radio run position SmartPort wiring leads have been extended and are receiving radio interference Replace lengthened wire with shielded cable to pro...

Страница 33: ...upported 48 Run times Eight settings from 1 to 30 min Range Up to 450 137 m ELECTRICAL SPECIFICATIONS Power Source Transmitter 9V alkaline battery Power Source Receiver 24 VAC 0 010 Amps from controller Transmitter type Saw Stabilized Receiver Type Superheterodyne System Operating Frequency 315 MHz Install SmartPort up to 50 feet from controller use shielded cable wiring harness See a A Word About...

Страница 34: ...eceiver on a Temporary Basis from Outside of a Garage or Building This installation is ideal for situations where a contractor desires the ability to access and operate a controller from outside of a locked building or garage However the SRR receiver must be removed from the SmartPort and the weather resistant cap placed back on the outlet after each use INSTALLATION DETAILS ...

Страница 35: ......

Страница 36: ...ries Incorporated The Irrigation Innovators 1940 Diamond Street San Marcos California 92069 TEL 1 760 744 5240 FAX 1 760 744 7461 2004 Hunter Industries Incorporated www HunterIndustries com P N 700432 LIT 220 5 04 ...

Отзывы: