10
11
AC AC R RS C MV 1 2 3 4 5 6
9 V Battery
Valve Common Wire
Connect the Two
Transformer Wires to
the Two AC Terminals
Transformer
Valve 1
Valve 2
Valve 3
Valve 4
Valve Wires
RESET
Connecting Valves and Transformer
1. Route control wires between control
valve location and controller. Typically
it is recommended that an 18 AWG
multi-wire sprinkler connection cable
be used. This type of connection is
insulated for burial and is color-coded
to help keep track of your connections.
2. At the valves, attach the common wire
to either solenoid wire of the valve.
This is most commonly the white
colored wire. Attach a separate control
wire to the remaining solenoid wire and
make a note of the color corresponding
to each valve and the watering station
it controls.
3. Secure the wires with a waterproof wire
connector to protect the connection.
4. Open hinged wiring compartment door
to access the terminal strip area shown
in the diagram.
5. Route the valve wires through the large
opening on the base of the cabinet or
through 1⁄2 inch conduit if installed.
Strip 1⁄4 inch of insulation from ends of
all wires.
INSTALLATION
6. Secure the white valve common
wire to the screw on the terminal
marked C. With the valve common
wire connected, connect the color-
coded wires from the valves to their
appropriate station numbers and tighten
the screws.
7. Route transformer cable through the
small hole in the bottom of the cabinet
and connect the wires to the two screws
marked AC.
Do not plug transformer
into power source until the
controller is mounted and all
valves have been connected.
SRC
Plus
Controller