18
19
Clearing Controllerʼs Memory/Resetting
Controller
If you feel that you have misprogrammed
the controller, there is a process that will
reset the memory to factory defaults and
erase all programs and data that have
been entered into the controller. Press
the , and and hold them down
simultaneously. Press and release the
reset button then release the , and
buttons. Time display should show 12:00
AM
.
All memory has been cleared and the
controller may now be reprogrammed.
Hunter Quick Check™
Irrigation professionals are continuously
looking for ways to more efficiently and
effectively diagnose programs in the field.
Instead of having to physically check each
field wiring circuit for potential problems,
the user can run the Hunter Quick Check
circuit test procedure. This circuit
diagnostic procedure is very beneficial
because of its ability to aid in quickly
identifying “shorts” commonly caused by
faulty solenoids or when a bare common
wire touches a bare station control wire.
To initiate the Hunter Quick Check test
procedure; Press the , , and and
buttons simultaneously. In the standby
mode, the LCD will display all segments
(helpful when troubleshooting display
problems). Press the button to begin
the Quick Check test procedure. Within
seconds, the system searches all stations
in an effort to detect a high current path
through the station terminals. When a field
wiring short is detected, an ERR symbol
preceded by the station number will
momentarily flash on the controller LCD
display. After the Hunter Quick Check
completes running this circuit diagnostic
procedure, the controller returns to the
automatic watering mode.
AC AC R RS C MV 1 2 3 4 5 6
9 V Battery
RESET
SRC
Plus
Controller