  Trouble Shooting

problem:

 Fan does not come on.

Solution:

   •  Hunter Fan Bath Ventilators are extremely quiet. To confirm that the fan is running, place your hand near the vents to feel 

the air movement.

    • Turn power on, replace fuse, or reset breaker.

    • Check all plug connections to be sure they are secure.

    • Check the wiring to make sure it matches the wiring diagram.

problem:

 Light does not come on. 

Solution:

    •  Replace the light bulb with a new bulb.

    •  Turn power on, replace fuse, or reset breaker.

    •  Check all plug connections to be sure they are secure.

    •  Check the wiring to make sure it matches the wiring diagram.

 

problem: 

Fan is noisy.

Solution:

    •  Check and tighten all fasteners.

   •  Check the glass to make sure it is secure.

    •  Check the flapper to make sure it moves freely.

If you need parts or service assistance, please call 888-80-12 or visit us at our WEB site at http://www.hunterfan.com.

011_41949_EngS_2-12-08.indd   19

2/12/08   2:44:09 PM

Содержание Riazzi 83001

Страница 1: ...2 12 2008 I n s t a l l a t i o n G u i d e 83001 Riazzi Bath Ventilator with Light READ and SAVE THESE INSTRUCTIONS ENGLISH See page 2 Espa ol Vea la p gina 21 011_41949_EngS_2 12 08 indd 1 2 12 08 2...

Страница 2: ...e same time C A U T I O N W arning 1 Use this unit only in a manner intended by the manufacturer If you have questions contact the manufacturer 2 Before servicing or cleaning the unit switch power off...

Страница 3: ...4 K 77520 01 L 65219 75184 01 133 96374 01 214 Extra Screws x2 D x2 3 8 Cable Connector 1 Turn off the power source Tools Needed Not supplied Estimated assembly time 30 to 60 minutes Before Installati...

Страница 4: ...the housing 3 I F Remove the pre loaded screw tip covers Remove the wiring cover screw 6 Back out the pre loaded screw tips until flush with the side of the housing Remove the wiring cover Remove pack...

Страница 5: ...ew Construction attaching to joist 10 B C Choose Installation Option For New Construction attaching to joist go to step A11 page 5 For New Construction suspended between joists go to step B11 page 8 F...

Страница 6: ...ther Option A13 0 A16 Route wires through strain relief For supply connection use wires suitable for at least 90 C 194 F Connect wires as shown Connect 4 duct and vent to the outside Tape joints If du...

Страница 7: ...THE WIRING HARNESS 0 0 0 0 A17 Reinstall the motor by inserting the tabs and pushing up into position Make sure the wires are not pinched between the motor and the housing 0 0 0 0 I A18 ON OFF A21 Tes...

Страница 8: ...ween the screw head and the joist Screws are not provided New Construction suspended between joists B11 E F 1 8 bit B14 B15 F B13 Position the correct depth mark at the bottom edge of the joist based...

Страница 9: ...White White Bare Copper Ground B19 Night Light Night Light Switch 1 AC In Main Switch 1 AC In Switch 2 AC In Option Fan Main Light Together Option B21 Connect 4 duct and vent to the outside Tape join...

Страница 10: ...I B23 Reinstall the motor by inserting the tabs and pushing up into position Make sure the wires are not pinched between the motor and the housing B25 Turn on the power source ON OFF B26 B24 J Test th...

Страница 11: ...ommodate the new motor housing 9 x 9 75 Cut out an opening for the housing Use the motor housing as a template to mark position Slide the mounting rails into brackets Position the correct depth mark a...

Страница 12: ...joist Screws are not provided Attach the rails onto the screws Tighten screws Connect 4 duct and vent to the outside Tape joints If ducting does not fit securely an adapter may need to be purchased R...

Страница 13: ...witch 1 AC In Switch 2 AC In Option Fan Main Light Together Option Tighten the strain relief screws Connect wires as shown C24 I H C23 G Install the wiring cover plate Make sure all wiring connections...

Страница 14: ...source Test the motor If the motor does not run check the plug connection C29 E1 Go to step on page 17 to attach grille Reinstall the motor by inserting the tabs and pushing up into position Make sur...

Страница 15: ...nd check to make sure the opening is large enough to accommodate the new motor housing 9 x 9 75 Move the housing into position above the ceiling Attach existing ducting to duct connector Tape joints I...

Страница 16: ...20 J Connect wires as shown Reinstall the motor by inserting the tabs and pushing up into position Make sure the wires are not pinched between the motor and the housing Connect wiring harness DO NOT A...

Страница 17: ...21 Test the motor If the motor does not run check the plug connection Turn on the power source Attaching the Grille Remove the thumbscrews Connect wiring harness DO NOT ALLOW THE FIXTURE TO HANG FROM...

Страница 18: ...ax 60 watt A 15 bulbs Not Included E8 Turn glass dome assembly as shown until it locks into position E6 O E7 Attach thumbscrews WARNING To reduce the risk of electrical shock all 4 thumbscrews MUST be...

Страница 19: ...diagram Problem Light does not come on Solution Replace the light bulb with a new bulb Turn power on replace fuse or reset breaker Check all plug connections to be sure they are secure Check the wiri...

Страница 20: ...IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES THE DURATION OF ANY IMPLIED WARRANTY INCLUD ING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IN RESPECT TO...

Страница 21: ...41949 02 02 12 2008 21 G u a d e i n s t a l a c i n Ventilador para ba o Riazzi 83001 con luz LEA y CONSERVE ESTAS INSTRUCCIONES Espa ol 011_41949_Sp_2 12 08 indd 21 2 12 08 2 46 25 PM...

Страница 22: ...ci n Nacional de Protecci n contra Incendios NFPA la Asociaci n de Ingenieros Americanos en Calefacci n y Aire acondicionado ASHRAE y los c digos locales 5 Al cortar o taladrar en paredes o techo no d...

Страница 23: ...1 214 Tornillos adicionales x2 D x2 Conector de cable de 3 8 1 Incluido 2 F J Apague la fuente de alimentaci n Herramientas necesarias no suministradas Tiempo estimado de ensamblaje entre 30 y 60 minu...

Страница 24: ...biertas de las puntas de tornillo precargadas Retire el tornillo de la cubierta del cableado Retire las puntas de tornillo precargadas hasta que est n a nivel con el lado del alojamiento Retire la cub...

Страница 25: ...viga seg n el espesor de su plancha de yeso Construcci n nueva fijaci n a la viga Escoja la opci n de instalaci n Para construcci n nueva fijaci n a la viga vaya al paso A11 p gina 25 Para construcci...

Страница 26: ...Conecte los alambres como se muestra Conecte un ducto de 4 y ventile hacia el exterior Aplique cinta a las uniones Si el ducto no se ajusta firmemente puede ser necesario comprar un adaptador Instale...

Страница 27: ...enda la fuente de alimentaci n Conecte el mazo de cables NO PERMITA QUE EL MOTOR CUELGUE DEL MAZO DE CABLES Vuelva a instalar el motor introduciendo las pesta as y levantando a su posici n Aseg rese q...

Страница 28: ...plantilla Introduzca los tornillos dejando espacio entre la cabeza del tornillo y la viga No se proporcionan los tornillos Construcci n nueva suspendido entre vigas Ubique la correcta marca de profund...

Страница 29: ...s tornillos Conecte los alambres como se muestra Conecte un ducto de 4 y ventile hacia el exterior Aplique cinta a las uniones Si el ducto no se ajusta firmemente puede ser necesario comprar un adapta...

Страница 30: ...GUE DEL MAZO DE CABLES Vuelva a instalar el motor introduciendo las pesta as y levantando a su posici n Aseg rese que los alambres no se pellizquen entre el motor y el alojamiento Encienda la fuente d...

Страница 31: ...acomodar el alojamiento del motor nuevo 9 x 9 75 Recorte una abertura para el alojamiento Utilice el alojamiento del motor como una plantilla para marcar la posici n Deslice los rieles de montaje en...

Страница 32: ...los Fije los rieles con los tornillos Apriete los tornillos Conecte un ducto de 4 y ventile hacia el exterior Aplique cinta a las uniones Si el ducto no se ajusta firmemente puede ser necesario compra...

Страница 33: ...ci n Ventilador y luz principal juntos Opci n Motor del ventilador C22 C24 I H C23 G Apriete los tornillos del aliviador de tensiones Conecte los alambres como se muestra Instale la placa de cubierta...

Страница 34: ...retando los 2 tornillos Encienda la fuente de alimentaci n Pruebe el motor Si el motor no funciona verifique la conexi n del enchufe Vuelva a instalar el motor introduciendo las pesta as y levantando...

Страница 35: ...posici n encima del techo Conecte el ducto existente con el conector de ducto Aplique cinta a las uniones Si el ducto no se ajusta firmemente puede ser necesario comprar un adaptador Instale el aloja...

Страница 36: ...20 J H D17 G Conecte los alambres como se muestra Vuelva a instalar el motor introduciendo las pesta as y levantando a su posici n Aseg rese que los alambres no se pellizquen entre el motor y el aloja...

Страница 37: ...1 M E2 Pruebe el motor Si el motor no funciona verifique la conexi n del enchufe Encienda la fuente de alimentaci n Fijaci n de la rejilla Retire los tornillos de mano Conecte el mazo de cables NO PER...

Страница 38: ...vatios como m ximo No incluidas E8 Gire el conjunto de la pantalla como se muestra hasta que quede trabada en posici n E6 O E7 Instale los tornillos de mano ADVERTENCIA Para reducir el riesgo de desc...

Страница 39: ...el diagrama de cableado Problema La luz no funciona Soluci n Reemplace la bombilla con una nueva Encienda la alimentaci n el ctrica reemplace el fusible o restablezca el interruptor autom tico Verifiq...

Страница 40: ...O DE CUALQUIER PARTE MET LICA DEL EXTRACTOR DE AIRE PARA BA O ESTAGARANT ASUSTITUYEATODAS LAS OTRAS GARANT AS EXPRESAS LADURACI N DE TODAGARANT AIMPL CITA INCLUYENDO PERO SIN LIMITARSE A CUALQUIER GAR...

Отзывы: