9
41473-01 12/6/2001
STEP 6 - HANGING THE
FAN
Sub-steps 1 and 2 apply to Flush, Standard, and Angle
mounting. Sub-step 3 applies to Standard and Angle
mounting only.
1. Swing the fan up so as to align the canopy screw
holes with the mounting holes on the ceiling plate.
Refer to Figure 6a.
2. Install and tighten the two #10-32 x 1/2" mounting
screws.
3. For Standard and Angle Mounting only: In addi-
tion to sub-steps 1 and 2, lift the fan housing to-
wards the ceiling and rotate the fan until each canopy
tab engages a groove in the hanger ball as shown in
Figure 6b.
Note: If the tabs are already engaged, do not rotate.
WARNING
Failure to complete sub-steps 1 through 3 could
cause fan to fall. (Sub-step 3 not applicable for
flush mounting.)
Figure 6a - Attaching Canopy to
Ceiling Plate
Ceiling
Plate
Canopy
Figure 6b - Canopy Tabs and Grooves
in Hanger Ball
Groove in
Hanger
Ball
Canopy
Tab
Groove in
Hanger Ball