23
REFERENCE
MAINTENANCE
TO PREVENT SERIOUS INJURY OR DEATH:
• BEFORE performing maintenance or service, ALWAYS disconnect the power by turning off the circuit breaker or
breakers to the fan locations and confirm Lockout/Tagout procedures are in place.
• If you cannot lock the circuit breakers in the off position, securely fasten a prominent warning device, such as a
tag, to the electrical panel.
• Do not remove covers while power is on.
Blade Cleaning
Depending on the commercial application, dust or other particulates can build up on the fan blades over time. At least every 12
months, a maintenance person or skilled trade professional, who has experience using a lift, should clean the blades using a rag or
sponge and hot water or regular cleaning solutions. DO NOT use chlorine or any chemicals containing chlorine or the blades may be
damaged.
Retention System Check
Each fan is installed with a retention system. Every 12 months, check that the retention cable is properly attached to the building struc-
ture. Inspect the visible portions of the retention cable for damage, including fraying.
The retention cable is an important part of the safety system and protects users in the unlikely event of a catastrophic situation. It is
critical for fan owners to ensure that it is intact and properly secured.
Replacement Parts
Please call 1-844-593-FANS (3267) for replacement parts.
Service
If the fan does not operate properly using the procedures in this manual, follow LockouVTagout procedures for your facility and lockout
all power to the unit and contact our Technical Department for further assistance at 1-844-593-FANS (3267).
ELECTRIC SHOCK HAZARD