INSTALLING THE APPLIANCE 

 

 

Pre-Installation Notes  

 

1.

 

Check the stove data plate to establish the gas type required. The data plate 
can be found on a chain at the top left rear corner of the stove. 

Before installation check that the local distribution conditions, nature of the 
gas and pressure, and adjustment of the application are compatible. 

 

2.

 

GAS SAFE REGISTERED INSTALLER

 or equally recognised competent 

person must fit the appliance. That person is legally responsible for the safe 

installation of the appliance with due regard to all relevant local and national 
building regulations. 

 

3.

 

All outer surfaces of the stove excepting the gas control knobs are defined as 
working surfaces. 

 

4. 

Installation site 

Any  installation  area  previously  used  for  a  solid  fuel  fire  or  stove  would 

probably be deemed suitable for the appliance. 
 

5.  The stove 

must  not

 be installed onto a combustible wall.  Any combustible 

materials must be removed from behind the appliance.  
 

6.   The appliance must be sited on a non-combustible hearth of minimum 12mm 

thickness. 

Diagram 1 

Содержание HS Gas SELENE 6 D

Страница 1: ...s instruction booklet with the user after the installation is complete Leave the system ready for operation and instruct the user in the correct use of the appliance and operation of its controls Plea...

Страница 2: ...ices 10 Fitting the Loose Ceramic Coals 11 Section B Fitting the Log Effect Ceramic Matrices 13 Fitting the Loose Ceramic Logs 14 RE ASSEMBLING THE STOVE 16 TEST FOR SPILLAGE 16 SPILLAGE MONITORING SY...

Страница 3: ...ar 37mBar Supply Gas Type Category G20 I2H G31 I3P Jet Type Size 82 380 92 190 Heat Input Gross Full Low 6 5kW 4 2kW 6 4 kW 3 7 kW Gas Flow Rate m3 h Full 0 62 m3 h 0 236 m3 h NOx Class 3 5 Efficiency...

Страница 4: ...ust fit the appliance That person is legally responsible for the safe installation of the appliance with due regard to all relevant local and national building regulations 3 All outer surfaces of the...

Страница 5: ...etween the appliance and the walls so that a satisfactory spillage test can be performed as detailed on page 16 MINIMUM CLEARANCE DISTANCES TO DIMENSION DESCRIPTION COMBUSTIBLE MATERIAL NON COMBUSTIBL...

Страница 6: ...be avoided The flue must have a minimum of 2 6 meters of vertical height measured from the top of the stove to the bottom of the terminal outlet Please note for rear flue appliances it is recommended...

Страница 7: ...Diagram 3 Completely remove the 2 securing bolts that are located behind the valve cover plate by using a 10mm spanner as shown in Diagram 4 Slacken the rear locating bolts with a 13mm spanner and re...

Страница 8: ...s have moved away from the glass panel The glass panel can then be lifted out Gas Supply Connections The appliance is supplied with an 8mm Bundy pipe and an 8mm compression elbow to allow easy connect...

Страница 9: ...t the appliance is measured with the appliance running at full rate For information on how to achieve full rate read Adjusting between High and Low Output Settings in the Lighting the Appliance sectio...

Страница 10: ...ow the instructions set out in Section B Fitting the Log Effect Ceramic Matrices Page 13 Section A Fitting the Coal Effect Ceramic Matrices NATURAL GAS The fire bed is constructed of 3 ceramic matrice...

Страница 11: ...the coal should rest on the middle ceramic Then take a small coal and place the front of it in the first left notch in the front ceramic the back of the coal resting on the centre ceramic Continue th...

Страница 12: ...row of coals and into the notches on the rear ceramic matrix shown in Diagram A14 Note Gaps must be left between the coals for the flames to pass through 7 The fire bed should now be completed The st...

Страница 13: ...the firebox B Place the middle ceramic matrix into the fire so that the flat surface sits on the burner tray Push the middle ceramic back until it rests against the rear ceramic shown in diagram B10 N...

Страница 14: ...two short branches coming from it It sits in the furthest left cut out on the front ceramic and rests in the groove on the centre ceramic shown in diagram B13 F The third log to be placed is the thin...

Страница 15: ...he large log and the shorter straight log The log should also rest on the join between the other 2 placed logs as shown in diagram B16 I The sixth and final log has a single branch coming from it and...

Страница 16: ...e the stove running at full rate for a further 10 minutes and repeat the test If there is a fan in an adjoining room the spillage test must be repeated with the fan running and all connecting doors be...

Страница 17: ...ocated on the right hand side of the valve Turn the main burner control knob Knob B diagram 20 fully anti clockwise until the end stop is reached Fit the motor as shown in diagram 21 making sure that...

Страница 18: ...control handset Test that the remote control system is working by pressing the increase and decrease buttons on the handset If the system is working correctly the receiver box can be sited The ideal...

Страница 19: ...ic matrices 4 Using a soft brush clean away any lint or light carbon soot deposits out of the gas ports on the burner top plate 5 Check the TTB Bracket inside the draught diverter for blockage and cle...

Страница 20: ...bly HG06 085 Coal Effect Ceramic Spares Small Ceramic Coal HG06 044 Medium Ceramic Coal HG06 045 Large Ceramic Coal HG06 046 Front Coal Effect Ceramic Matrix HG06 041 Middle Coal Effect Ceramic Matrix...