TESTING SUPPLY PRESSURE
Gas pressure at the appliance is measured via the T-piece going to the control valve (circled in figure 5).
Turning the screw approximately half a turn anti-clockwise with a small flat-bladed screwdriver opens
the test point.
ALWAYS CLOSE TEST POINTS AFTER USE!
The gas pressure at the appliance is measured with the appliance running at
full rate
.
(For information on how to achieve ‘full rate’ read ‘Adjusting Between High and Low Output Settings’ in
the ‘Lighting the Appliance’ section of the User
Instructions).
Inlet Gas Pressure should be:
20mbar ± 1.0mbar for Natural Gas
37mbar for LPG
The supply pressure test point (shown in figure 6) is measured at the burner inlet point.
INSTALLATION OF THE FIRE-BED INTO THE STOVE
IMPORTANT NOTE
CERAMIC COALS AND LOGS GET VERY HOT! NEVER ATTEMPT TO HANDLE HOT COALS OR
LOGS WITH BARE HANDS AND NEVER PLACE HOT COALS OR LOGS ON OR NEAR
COMBUSTIBLE SURFACES.
HUNTER STOVES LTD ACCEPTS NO RESPONSIBILITY FOR ANY INJURY HOWEVER CAUSED
WHILST HANDLING HOT COALS, LOGS OR CERAMICS.
FIRE-BED ARRANGEMENT AND INSTALLATION
This appliance can be fitted with log effect ceramics. The fire-bed is constructed of a base ceramic and 6
loose logs.
Figure 3: Supply Pressure Test Point
Inlet Pipe Location
Loose Log Ceramics