Speed Dome Camera Instruction Manual
12/33
DIP Switch Setup
Before installing the camera, set up the DIP switch to configure the camera ID and the
communication protocol.
Camera ID Setup
ON
ON
1
2
3
4
5
6
7
8
z
ID numbers of cameras are set up with binary numbers.
See the examples shown below.
Pin
1
2
3
4
5
6
7
8
Binary Value
1
2
4
8
16
32
64 128
ex) ID=5
on
off on
off
off
off
off
off
ex) ID=10
off
on off
on
off
off
off
off
z
The camera ID range is “1~255”.
Camera ID must not be
“0”!
z
The factory default of the camera ID is “1”.
z
Match the camera ID with the Cam ID setting of your DVR
or Controller to control the camera.
z
If you are connecting a single camera to a controller,
terminate the camera. When connecting more than one
camera to a single controller, terminate the last camera on
the communication line. The last camera means the camera
farthest in cable length from the controller.
z
Note that the total length of the communication cable
between a controller and the camera(s) on the same
communication line must be less than 1.2Km.
INSTALLATION