5. The unit comes on before I press the POWER-MENU key, and won’t turn off.

Check the transducer cable — if the outer jacket of the cable has been cut and the cable is in contact with bare metal, you will need
to repair the cut with electrical tape. If there is no problem with the cable, disconnect the transducer from the unit and see if the prob-
lem is corrected, to confirm the source of the problem.

6.  I get gaps in the reading at high speeds.

Your transducer needs adjusting. If the transducer is transom-mounted, there are two adjustments available to you: height, and running
angle. Make small adjustments and run the boat at high speeds to determine the effect. It may take several tries to optimize high-speed
operation. This can also be a result of air or turbulence in the transducer location caused by rivets, ribs, etc.

7.  My unit loses power at high speeds.

Your PiranhaMax has over-voltage protection that turns the unit off when input voltage exceeds 20 VDC. Some outboard motors do not effec-
tively regulate the power output of the engine’s alternator and can produce voltage in excess of 20 Volts when running at high RPMs.

8.  The display begins to fade out. Images are not as sharp as normal.

Check the input voltage. The PiranhaMax will not operate on input voltages below 10 VDC.

9.  The display shows many black dots at high speeds and high sensitivity settings.

You are seeing noise or interference caused by one of several sources. Noise can be caused by electronic devices. Turn off any near-
by electronics and see if the problem goes away. Noise can also be caused by the engine. If engine noise is causing the interference,
the problem will intensify at higher RPMs. Increase the engine speed with the boat stationary to isolate this cause. Propeller cavita-
tion can also appear as noise on the display. If the transducer is mounted too close to the propeller, the turbulence generated can
interfere with the sonar signal. Make sure that the transducer is mounted at least 15" (380 mm) from the propeller.

International Purchases

A separate warranty is provided by international distributors for units purchased outside the United States. This warranty is includ-
ed by your local distributor and this distributor maintains local service for your unit. Warranties are only valid in the area of intend-
ed distribution. Units purchased in the United States or Canada must be returned to our factory in the United States for service. 

Содержание Piranha Max 10

Страница 1: ...fication of the serial number or attempt to repair the original equipment or accessories by unauthorized individuals will void the warranty Handling and or opening this unit may result in exposure to...

Страница 2: ...y pressing the RIGHT Arrow Key twice See SetUp Menu for more information The Menu System A simple menu system allows you to access your PiranhaMax s adjustable settings To activate the menu system pre...

Страница 3: ...ault Auto NOTE In manual operation if the depth is greater than the depth range setting the bottom will not be visible on the display Select AUTO to return to automatic operation Zoom Setting Not Save...

Страница 4: ...Setting Saved in Memory Press the POWER MENU key until FILTER appears Select either Off or On Filter adjusts the sonar filter to limit interference on the display from sources such as your boat engin...

Страница 5: ...p menu choices to exit the SetUp menu NOTE Returns from the 200 kHz narrow beam are shown with shaded fish symbols while the 83 kHz wide beam returns are displayed with hollow fish symbols NOTE Hollow...

Страница 6: ...ss the POWER MENU key until LANGUAGE appears International Units Only LANGUAGE selects the display language for menus Settings vary Default English Scroll through all SetUp menu choices to exit the Se...

Страница 7: ...ector is reversed the unit will not work Examine the contacts on the back of the unit to ensure there is no corrosion 2 There is no transducer detected The PiranhaMax has the ability to detect and ide...

Страница 8: ...g at high RPMs 8 The display begins to fade out Images are not as sharp as normal Check the input voltage The PiranhaMax will not operate on input voltages below 10 VDC 9 The display shows many black...

Страница 9: ...P Pi ir ra an nh ha aM Ma ax x1 10 0 S Sp pe ec ci if fi ic ca at ti io on ns s Depth Capability 600 feet 180 m Power Output 100 Watts RMS Sonar Operating Frequency 200 kHz Single Beam Sonar Coverage...

Страница 10: ...MISE EN GARDE Ne manipulez pas le dessous du transducteur lorsqu il met un signal sonar Un contact prolong avec le transducteur peut causer un inconfort physique ou une irritation du tissu cellulaire...

Страница 11: ...uatique sont affich s l cran lorsqu ils sont d tect s Les conditions subaquatiques varient consid rablement Il faut donc interpr ter les r sultats et poss der une certaine exp rience pour comprendre t...

Страница 12: ...u R glages partir du syst me de menus principal vous pouvez acc der des options compl mentaires du menu des r glages Voir la section traitant du menu R glages pour obtenir de plus amples renseignement...

Страница 13: ...es conditions de profondeur actuelles Vitesse de d filement Ce r glage est sauvegard en m moire Appuyez sur la touche Mise en marche Menu POWER MENU jusqu ce que le menu Vitesse de d filement CHART SP...

Страница 14: ...m moire Appuyez sur la touche Mise en marche Menu POWER MENU jusqu ce que le menu R glages SetUp s affiche S lectionnez soit D sactiv e Off soit Activ e On Activ e On d sactiv e Off valeur par d faut...

Страница 15: ...oles de poisson vides ne sont affich s que sur les appareils mettant un double faisceau de 200 kHz et 83 kHz Affichage du fond du menu R glages Ce r glage est sauvegard en m moire Assurez vous de s le...

Страница 16: ...inie au menu d sactiv e Off 8 5 V 13 5 V valeur implicite d sactiv e Off Parcourez toutes les options du menu R glages pour quitter ce menu Langue mod les internationaux uniquement Ce r glage est sauv...

Страница 17: ...ension V rifiez les connexions du c ble d alimentation aux deux extr mit s Assurez vous que le c ble est branch correctement une source d alimentation fiable fil rouge la borne positive et fil noir la...

Страница 18: ...oir effectuer de nombreux r glages pour optimiser le fonctionnement grande vitesse Le probl me peut aussi tre caus par le frottement de l air ou la turbulence l emplacement du transducteur caus e par...

Страница 19: ...Beam Couverture sonar double faisceau 20 10 dB 200kHz 60 10 dB 83 kHz cran cristaux liquides 160V x 132H PiranhaMax15 240V x 160H PiranhaMax20 Transducteur XHS 9 20 T Longueur du c ble de transducteu...

Отзывы: