![Hughes HN9260 Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/hughes/hn9260/hn9260_user-manual_2182046008.webp)
Also, make sure that the power supply to the HN9260 is correct. The power supply should be
Part # 1031105-0001. Try power-cycling the HN9260 by unplugging the power cords from
the wall outlet and then plugging them back in.
7
The receiver is locked to an unknown network.
This condition should only be seen during installation and occurs when the receiver is locked
to a signal but there is no YahClick Network ID on that signal.
If this occurs during pointing or commissioning, the antenna has not been pointed correctly.
If it occurs during normal operation, it may be due to the user changing acquisition
parameters, including frequency and/or location of satellite, or the antenna becoming
misaligned. The former condition can be corrected by re-commissioning the site. The latter
requires an antenna repointing.
8
The receiver cable and transmit cable are switched.
This condition should only be seen during installation and occurs when the receive and
transmit cable are switched. The problem can be corrected by switching the cables to the
correct connections.
9
The receiver cable is shorted.
This condition occurs when the center (inner) conductor is touching the external braid
(outer conductor). Please check and possibly replace the cable.