PELLET STOVE 

OPERATING & INSTALLATION INSTRUCTIONS 

 

 

 

 

WESTPOINT PELLET STOVE 

 
 

 
 

 

1871 Route 9H 

 

Hudson, NY 12534 

 U.S.A. 
 Phone: 

518-828-6363 

 

Fx: 

  518-828-5639 

Please read this entire manual before installation and use of this pellet fuel burning room 
heater.  Failure to follow these instructions could result in property damage, bodily injury or 
even death. 
Contact your local building officials about restrictions and installation inspection 
requirements in your area. 
Save these instructions. 

Содержание Westpoint

Страница 1: ...5639 Please read this entire manual before installation and use of this pellet fuel burning room heater Failure to follow these instructions could result in property damage bodily injury or even deat...

Страница 2: ...ons 6 Operating Instructions 7 10 Thermostat Installation 11 Clearances to Combustibles 13 Installing Your Room Heater 12 21 Mobile Home Installations 23 Vent Termination Locations 24 Maintenance 25 2...

Страница 3: ...mum Standard grade Moisture Content 8 maximum Heat Content minimum 8 200 btu hr It is important to note that the ash content of the fuel and frequency of operation determine the frequency of cleaning...

Страница 4: ...to an outside combustion air source It is recommended that the exhaust vent be cleaned bi annually or after every two tons of pellets Soot or creosote may accumulate when the stove is operated under i...

Страница 5: ...use outdoor air for combustion Always install a manufactured fresh air intake kit from outside of the residence See the Installation section for the correct part numbers when ordering these component...

Страница 6: ...6 SPECIFICATIONS Heating Specifications Burn Rate 6 5lbs hr on 5 setting 55 000 60 000 Btu s hr Hopper Capacity 130 lbs Depends on quality and heating value of pellet fuel DIMENSIONS Figure 1...

Страница 7: ...oard functions and familiarize yourself with how the pellet stove works It is in this mode that the heat level for the AUTO and T STAT mode is set To Start up a Cold Stove Press and release the On Off...

Страница 8: ...may do so by pressing the FAN button If the flame goes out or the heat output is too high on minimum heat level setting use the AUGER TRIM button to make adjustments See the AUGER TRIM button descript...

Страница 9: ...o make heat level adjustments If the stove is warm at restart the On Off button must be pressed down and held for 2 seconds or more until the minimum heat level setting light is lit Heat Level When pr...

Страница 10: ...actory setting and works for most types of fuel Figure 2 Control Panel Open Door If the door is opened while the unit is operating it must be closed within 30 seconds or the unit will go into vacuum e...

Страница 11: ...t Disconnect unit from power supply Open right side panel to gain access to rear of control panel Take the thermostat wires and connect to the green screw terminal on the rear of the control panel see...

Страница 12: ...cified in NFPA 211 or the applicable building and mechanical codes If factory built the chimney specified shall be listed to the requirements of UL 103 or ULC S629M or if masonry shall meet the constr...

Страница 13: ...13 CLEARANCES TO COMBUSTIBLES INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER Figure 4 Figure 5...

Страница 14: ...the instructions which come with the wall thimble for this step 9 Install the appropriate length of exhaust vent pipe into the wall thimble See step 11 when determining the correct length of exhaust...

Страница 15: ...d horizontal termination cap or if necessary install a 90 elbow and appropriate length of vertical venting A listed vertical vent cap is recommended however if local codes allow when the vent terminat...

Страница 16: ...nt joint connections with 3 screws Seal the exhaust vent joint connections with high temperature silicone sealant 4 Install the combustion air intake pipe 5 Install a tee with a cleanout on the exhaus...

Страница 17: ...xhaust vent through the wall be sure to make sure that 3 75 mm clearances to combustibles are maintained 9 Secure all vent joint connections with 3 screws Seal the exhaust vent joint connections with...

Страница 18: ...18 Figure 9...

Страница 19: ...19 SELKIRK DIRECT TEMP VENT SYSTEM FOR PELLET APPLIANCES Images courtesy of Selkirk...

Страница 20: ...20 SELKIRK DIRECT TEMP VENT SYSTEM FOR PELLET APPLIANCES Images courtesy of Selkirk UP OUT HORIZONTAL TERMINATION KIT Figure 10...

Страница 21: ...21 SELKIRK DIRECT TEMP VENT SYSTEM FOR PELLET APPLIANCES Images courtesy of Selkirk STRAIGHT OUT HORIZONTAL TERMINATION KIT Figure 11...

Страница 22: ...22 SELKIRK DIRECT TEMP VENT SYSTEM FOR PELLET APPLIANCES Images courtesy of Selkirk THROUGH THE ROOF VERTICAL TERMINATION KIT Figure 12...

Страница 23: ...he holes provided in the pedestal base Ensure that the unit is permanently electrically grounded to the chassis of your home IT IS MANDATORY TO TAKE THE COMBUSTION AIR FROM THE OUTSIDE WHEN INSTALLING...

Страница 24: ...F 12 30 cm To outside corner G 12 30 cm To inside corner combustible wall H 3 91 cm within a height of 15 4 5 m above the meter regulator assembly To each side of center line extended above natural g...

Страница 25: ...ing the burn pot Inspect the burn pot regularly to check that the holes have not become plugged If necessary clean thoroughly It is imperative that the burn pot be re installed the correct way or the...

Страница 26: ...osed of by burial in soil or otherwise locally dispersed they should be retained in the closed container until all cinders have been thoroughly cooled Cleaning Heat Exchanger Tubes Your unit is design...

Страница 27: ...ld up continuously it may impede the exhaust flow 3 Inspection of Vent System The chimney venting system should be inspected should be inspected annually or per ton of fuel to determine if creosote or...

Страница 28: ...door frame Replace only with ceramic glass obtainable from the dealer Task Maintenance Schedule Burn Pot check daily Combustion Chamber weekly Heat Exchanger Tubes bi weekly Ash Pan bi weekly or every...

Страница 29: ...switch trips again contact your local dealer for service Condition 3 Exhaust blower does not operate normally Check all wiring connections Condition 4 Convection blower does not operate normally Check...

Страница 30: ...liner then the fire is going out before the unit shuts off On the control panel turn the heat level up to the next setting poorer quality pellets require a slightly higher setting Condition 10 Glass...

Страница 31: ...31 WIRING DIAGRAM...

Страница 32: ...s well as voiding the Warranty Item Part control panel circuit board SPSW1008 auger motor SPSW1006 250 F normally open high limit snap disc SPSA1016 140 F normally open exhaust temperature snap disc S...

Страница 33: ...rized Inca Metal dealer and is subject to the following conditions and limitations This factory warranty is nontransferable and may not be extended whatsoever by any of our representatives A licensed...

Страница 34: ...product its components or accessories are excluded Inca Metal neither assumes nor authorizes any third party to assume on its behalf any other liabilities with respect to the sale of this product Inca...